Cover Assembly
To remove the cover assembly:
1. Remove the front panel. (See
Front Panel
.)
2. Remove the two 1/4-in. hex-head screws that
attach the cover assembly to the washer.
3. Lift the cover assembly approximately 4 inches,
open the lid, and then remove the 2 Phillips-
head screws that attach the lid lock.
5. Pull the cover assembly from the washer.
4. Reach under the cover assembly, and then
fi
rmly press in on the front lock tab to release
the lid switch. Push it up from the opening in the
cover assembly.
Tab
Lid Switch
Disconnect
Tub Outlet Hose
Pump Outlet
Hose
Drain Pump
The drain pump receives 120 VAC from control
board location J7 pin 3 to pin 6.
The drain pump motor has an approximate
resistance value of 12
:
.
Note:
• The pump runs whenever the washer is in the
spin function of a cycle.
• The drain pump will operate if an over
fi
ll
condition has occurred (Over
fl
ow protection),
and 120 VAC is present at control board location
J8 pin 1 to pin 2. The pump will lower the water
level to the setting selected on the LOAD SIZE
control.
The drain pump is located in the bottom left front of
the unit. The outlet hose from the bottom of the tub
uses a 5/16-in. hex-head hose clamp at the tub and
spring clamps at the input and output of the pump.
To remove the drain pump:
1. Remove the front panel. (See
Front Panel
.)
2. Disconnect the pump wires.
Note:
Water will remain in hoses even when the tub
appears empty. Use care to avoid water spills.
3. Remove the spring clamps and hoses from the
pump.
4. Remove two 1/4-in. hex-head screws that
attach the drain pump to the washer chassis.