– 25 –
To replace the dryer start switch:
1. Follow steps 1 and 2 above.
2. Disconnect the wires from the start switch.
3. Lift the locking lever and rotate the start switch
counterclockwise.
Locking Lever
Voltage-Dropping Resistor
Dryer Front Panel
To remove the front panel:
Note:
In the following step, removing the dryer door
allows for easier manipulation of the dryer front
panel.
1. Remove the bottom screw from each hinge and
loosen the top screw, then lift the door off the
dryer front panel.
2. Remove the service panel. (See
Service Panel
.)
3. Remove the 2 Phillips-head screws and the heat
shield from the cabinet.
Note:
In the following step, cover the top of the
washer with a protective surface.
4. Disengage the control panel from the front
panel. (See
Control Panel
.), then place it on top of
the washer.
Loosen
Remove
Loosen
Remove
(Continued Next Page)
Timer Voltage - Dropping Resistor
The timer voltage-dropping resistor (on electric
models) controls the run-time during automatic
cycles. This 4500-ohm resistor is in series with the
timer motor. When the drum outlet thermostat
opens, turning off the heat – the resistor drops the
240 VAC heater circuit to 120 VAC to run the timer
motor.
Note:
If an open timer motor is present, or if the
timer fails to advance a properly heating automatic
cycle to the cool down position, check for 4500
ohms resistance at timer contacts A to T with the
timer in the off or cool down position.
The resistor is held in place on the bracket with a
single Phillips-head screw and has 2 wires attached.
Summary of Contents for Spacemaker GTUP270EMWW