Burner Output Rating - Natural Gas 5 in. W.C.P.
Burner
BTU Rate
Orifi ce Size
RF
18,000
No. 49
RR
5,000
No. 56
LF
11,000
No. 52
LR
9,100
No. 54
Bake 15,000
Broil 12,000
Burner Output Rating - L.P. Gas 10 in. W.C.P.
Burner
BTU Rate
Orifi ce Size
RF
15,000
No. 59
RR
5,000
No. 69
LF
11,000
No. 63
LR
9,100
No. 65
Bake 15,000
Broil 12,000
Relay Contacts Operation Test and Control
Voltage Check
Terminals
Voltage
L1- to N
120 VAC all the time
BAKE to N 120 VAC when in BAKE mode
BROIL to N 120 VAC when in BROIL mode
Switch Contacts
Door Motor
to N
120 VAC locking or unlocking
NOTE
Temperature/Mode Selection Necessary for
•
operation of Relay contacts.
Voltage must be present across terminals L1 to
•
N for control to operate. Transformer primary is
150 to 200
Ω
measured “L1” to “N” with power
removed.