– 59 –
Test Mode
Press
Displays
Exit
Key Continuity
Enter
The control will sound the beep as long as a key is
pressed.
Press
POWER
button to return to
test mode menu.
Outlet
Thermistor
Enter
The control shall display the Outlet Thermistor
•
temperature in degrees Fahrenheit on the VFD
during the test.
Pressing the
•
START/PAUSE
button shall turn on
the drum motor and blower motor, and turn on the
inner coil for electric dryer and the low
fl
ow gas
valve for gas dryer.
The control shall turn off the motor and inner coil
•
heater/gas valve before exiting this test.
Press
POWER
button to return to
test mode menu.
Inlet
Thermistor
Enter
The control shall display the inlet thermistor
•
temperature in degrees Fahrenheit on the VFD
throughout the duration of the test.
Pressing the
•
START/PAUSE
button shall start the
drum motor and turn on the inner and outer coils
for electric dryer and low
fl
ow and high
fl
ow gas
valves for gas dryer.
For every 30 seconds of run time, the control shall
•
reverse the direction of the drum.
Throughout the duration of the test, the VFD shall
•
display the state of the centrifugal switch (as
monitored by the micro input pin). It shall indicate
whether the control thinks the switch is open or
closed.
The control shall turn off the drum motor and turn
•
off the inner and outer coil heater/gas valve before
exiting this test.
Press
POWER
button to return to
test mode menu.
Moisture
Sensor
Enter
The control shall display the voltage read from the
moisture sensor in volts on the VFD.
Press
POWER
button to return to
test mode menu.
Blower/
Exhaust
Enter
The control shall turn on the blower motor and
•
display speed of the blower in RPM on the VFD.
*
Based on blower RPM, the control displays
•
Open
Exhaust
(less than 2900 RPM),
Dirty Exhaust
(between 2900 and 3100 RPM), or
Blocked Exhaust
(greater than 3100 RPM), to indicate exhaust
condition.
Press
POWER
button to return to
test mode menu.
Dryer Rack
Enter
Control enables the dryer rack cycle and displays the
inlet thermistor temperature in degrees Fahrenheit on
the VFD during the test.
Press
POWER
button to return to
test mode menu.
*
The maximum dryer air
fl
ow is 150 CFM (cubic feet per minute). The service mode does not provide
information about CFM. The only information that is provided is the condition of the exhaust system
represented by blower motor RPM. Blower motor RPM will increase as the dryer exhaust system becomes
partially restricted or restricted.
Summary of Contents for Profile DPVH880EJ
Page 27: ... 27 Airflow Gas Dryer Electric Dryer ...
Page 31: ... 31 Control Board Assembly Electric and Gas Models Front View Rear View J3 ...
Page 66: ... 66 Drum Motor Circuit Electric Models Drum Motor Circuit Gas Models ...
Page 67: ... 67 Blower Motor Circuit Electric Models Blower Motor Circuit Gas Models Gas Valve Circuit ...