– 53 –
Outlet Control Backup Thermostat
The outlet control backup thermostat is located
on the upper, rear area of the blower housing. It is
above the outlet control thermistor and the rack dry
thermostat. The outlet control backup thermostat
monitors the outgoing air temperature.
If the thermostat reaches a temperature beyond its
maximum temperature rating, it will trip and disable
power to the heating elements or burner assembly.
The outlet control backup thermostat opens at
165°F (74°C) and will automatically reset at 155°F
(68°C).
To remove the outlet control backup thermostat:
Remove the drum. (See
1.
Drum
.)
Disconnect the 2 wires from the outlet control
2.
backup thermostat.
Remove the Phillips-head screw that attaches
3.
the outlet control backup thermostat to the
blower housing.
Rack Dry Thermostat
The rack dry thermostat is located on the upper rear
area of the blower housing. It is above the outlet
control thermistor. The rack dry thermostat monitors
the outgoing air temperature.
If the thermostat reaches a temperature beyond its
maximum temperature rating, it will trip and disable
power to the heating elements or rack dry Calrod
element.
The rack dry thermostat opens at 130°F (54°C) and
will automatically reset at 115°F (46°C).
Note:
On electric models, if the drum light is
activated by selecting
DRUM LIGHT
on the control
panel during the rack dry cycle, the rack dry
interlock relay will open and heater operation will
stop.
To remove the rack dry thermostat:
Remove the drum. (See
1.
Drum
.)
Disconnect the 2 wires from the rack dry
2.
thermostat.
Remove the 2 Phillips-head screws that attach
3.
the rack dry thermostat to the blower housing.
Outlet Control
Backup Thermostat
Rack Dry
Thermostat
Electric Model Shown
Electric Model Shown
Summary of Contents for Profile DPVH880EJ
Page 27: ... 27 Airflow Gas Dryer Electric Dryer ...
Page 31: ... 31 Control Board Assembly Electric and Gas Models Front View Rear View J3 ...
Page 66: ... 66 Drum Motor Circuit Electric Models Drum Motor Circuit Gas Models ...
Page 67: ... 67 Blower Motor Circuit Electric Models Blower Motor Circuit Gas Models Gas Valve Circuit ...