11
—
Model
PRO AIR I112 OUT
PRO AIR 218 OUT
Compressor type
EU1011DV
5PS108EAA22
Compressor type
Rotary type
Locked rotor current
33.5
18
Compressor running current
4
4.05
Compressor input power
628
880
Compressor overload model
4CYC11233
7100819 (KA-122-LPD021A)
Throttling method
Capillary
Starting mode
Capacitor
Working temperature range
-
7
~
43
℃
Condenser
Aluminum fin-copper tube
Pipe diameter
Φ
9.52
Row-fin distance (mm)
2-1.4
2-1.8
Developed area of heat exchanger (I
×
H
×
L)
645
×
508
×
44
730
×
660
×
44
Fan motor speed (rpm)
830
815
Motor rated power (W)
30
60
Fan motor running current (A)
0.3
0.6
Fan capacitor (
μ
f)
2.5
3
Fan type-piece
/
Fan type-piece
Axial flow fan-1
Fan diameter (mm)
Φ
400
Φ
400
Defrosting method
Auto
Climate type
T1
Insulation class
I
Waterproof level
IP24
Maximum working pressure of exhaust
side (Mpa)
3.8
Maximum working pressure of exhaust
side (Mpa)
1.2
Noise (sound pressure level) dB(A)
54
60
Noise (sound pressure level) dB(A)
64
70
Outline dimension (W/D/H) (mm)
848
×
320
×
540
950
×
340
×
685
Package dimension (W/D/H) (mm)
878
×
360
×
600
1100
×
450
×
750
Net weight/gross weight (kg)
41/43
65/70
Outdoo
r unit
Refrigerant/refrigerant charge (kg)
R410A /1.2
R410A /0.9
×
2
Length 4
Liquid pipe
(mm)
Φ
6
Outer
diameter
Gas pipe
(mm)
Φ
9.52
Height
(m)
5
Conn
ectio
n
pipe
Maximum
distance
Length
(m)
10
Summary of Contents for PRO AIR 107
Page 2: ... 1 Summary and features Model Remark PRO AIR 107 IN PRO AIR 107 OUT 1Ph 230V 50Hz R410A 1 ...
Page 4: ... 3 Model Remark PRO AIR 218 IN PRO AIR 218 OUT 1Ph 230V 50Hz R410A ...
Page 5: ... 4 Model Remark GE AIR 326 IN1 GE AIR 326 IN2 GE AIR 326 OUT 1Ph 230V 50Hz R407C ...
Page 6: ... 5 Model Remark GE AIR 428 IN GE AIR 428 OUT 1Ph 230V 50Hz R407C ...
Page 20: ... 19 4 2 Outline and installation dimensions of indoor unit 20 Handle 60cm Bolt Nut Spanner ...
Page 71: ... 70 Explosive view and parts list Explosive view of parts and components of indoor unit 9 ...
Page 75: ... 74 Explosive view of parts and components of outdoor unit ...
Page 77: ... 76 Explosive view of parts and components of outdoor unit frequency converter ...
Page 79: ... 78 Explosive view of parts of outdoor unit one driving two ...
Page 81: ... 80 Explosive view of parts of outdoor unit one driving three ...
Page 83: ... 82 Explosive view of parts of outdoor unit one driving four ...
Page 101: ... 100 ...