86
—
Installing indoor unit
Installing the wall-mounting board
z
Use hanging line to find a horizontal
position. Since the drainage pipe outlet is
on the left side, make the left side on the
slightly lower side when adjusting the
mounting board.
z
Fix the rear panel on the wall by bolt.
z
Pull the mounting board after installation
to see if it is firm enough. The mounting
board should be able to withstand the
weight of an adult (60 kg) after installation,
and the weight should be evenly shared
by each screw.
Drill the piping hole
z
As shown in Fig. 11-2, pipe can go out from
6 directions. Select one of them according
to the needs.
z
After determining the hole location as
shown in Fig. 11-1, drill a downward inclined
hole(
φ
55
)
.
z
Wall pipes should be adopted in order to
protect tubing and cable from being
damaged when they pass through the hole.
nstalling the water drainage pipe
z
Drainage hose must be placed at a
downward slant for smooth drainage.
z
Do not wrench or bent, fluctuate etc, and
do not flood its end by water.(as shown in
Fig.11-3
)
z
When long drainage hose goes through
the indoor unit, it should be wrapped with
insulating materials.
Fig. 11-3
Installing the connecting pipe
Connect the connecting pipe with the two outlet pipes of indoor unit and tighten the joint nut of the
connecting pipe(refer to “Installation of connecting pipes” below
)
.
Note:
z
Connect the connecting pipe with indoor unit first, and then outdoor unit.
z
The curving arrangement of the pipe must be done carefully and do not damage the
connection pipe.
z
Do not tighten the joint nut too much, or it will cause leakage.
Rear left piping Rear right piping
Right
Rear right
Lower right Rear left
Lower left
Left
Fig. 11-2
Bulge
Wrenched
Immerged in the water
Fig. 11-1
Summary of Contents for PRO AIR 107
Page 2: ... 1 Summary and features Model Remark PRO AIR 107 IN PRO AIR 107 OUT 1Ph 230V 50Hz R410A 1 ...
Page 4: ... 3 Model Remark PRO AIR 218 IN PRO AIR 218 OUT 1Ph 230V 50Hz R410A ...
Page 5: ... 4 Model Remark GE AIR 326 IN1 GE AIR 326 IN2 GE AIR 326 OUT 1Ph 230V 50Hz R407C ...
Page 6: ... 5 Model Remark GE AIR 428 IN GE AIR 428 OUT 1Ph 230V 50Hz R407C ...
Page 20: ... 19 4 2 Outline and installation dimensions of indoor unit 20 Handle 60cm Bolt Nut Spanner ...
Page 71: ... 70 Explosive view and parts list Explosive view of parts and components of indoor unit 9 ...
Page 75: ... 74 Explosive view of parts and components of outdoor unit ...
Page 77: ... 76 Explosive view of parts and components of outdoor unit frequency converter ...
Page 79: ... 78 Explosive view of parts of outdoor unit one driving two ...
Page 81: ... 80 Explosive view of parts of outdoor unit one driving three ...
Page 83: ... 82 Explosive view of parts of outdoor unit one driving four ...
Page 101: ... 100 ...