CHAPTER 1: INTRODUCTION
INTRODUCTION
MULTILINK ML3000 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL
1–7
WEIGHT
ML3000 ethernet switch........ 14.2 lbs. (6.5 kg)
1.3.4
Compliance
TEST
REFERENCE STANDARD
TEST LEVEL
Electrostatic Discharge
EN61000-4-2
Level 4
RF immunity
EN61000-4-3
Level 3
Fast Transient Disturbance
EN61000-4-4
Level 3 & 4
Surge Immunity
EN61000-4-5
Level 4
Conducted RF Immunity
EN61000-4-6
Level 3
Power magnetic Immunity
IEC61000-4-8
Level 3
Voltage Dip & interruption
IEC61000-4-11
0, 40, 70% dips, 250/300cycle
interrupts
Ringwave Surge
IEC61000-4-12
Level 4
Radiated & Conducted Emissions CISPR22
Class A
Radiated & Conducted Emissions FCC Part 15 Subpart B
Class A
Random Vibration
EN61373
Class A
Shock
EN61373
30g
Safety
EN60950-1
standard
Power Interruption
NEMA TS2
1500 msce, 450 msec
interrupts
Power Transients high repetition
NEMA TS2 2.1.6.1:2003
300V,2500W
Power Transients (low repetition
high energy)
NEMA TS2 2.1.6.2 :2003
600V , 1 ohm impedance
Transients I/O terminals
NEMA TS2 2.1.7.1 :2003
300V, 1000 ohms impedance
Non Destructive transient
Immunity
NEMA TS2 2.1.8 :2003
1000V, 1 ohm X 3
Operational frequency
NEMA TS2 -57-63Hz
60Hz +/- 3Hz
RF Immunity
IEEE C37.90.2
20V/m 80-1Ghz
Trapezoid Surge
EN50155
1800 V
Oscillatory Surge
IEC61850-3
Level 4 (4 kV)
Harmonic Current Measurement
EN61000-3-2
+/- 5%
Voltage Fluctuations and Flicker
EN61000-3-3
Standard Limits
Dielectric
IEEE 1613
2KV & 500V
Impulse
IEEE 1613
5KV