MULTILINK ML3000 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL
8–1
Multilink ML3000
Ethernet Communications Switch
Chapter 8: Access using
GE Energy
Access using
8.1
Introduction to
8.1.1
Overview
The protocol (short for Terminal Access Controller Access Control System)
provides access control for routers, network access servers and other networked
computing devices via one or more centralized servers. provides separate
authentication, authorization and accounting services.
TACACS allows a client to accept a username and password and send a query to a TACACS
authentication server, sometimes called a TACACS daemon (server) or simply TACACSD. This
server was normally a program running on a host. The host would determine whether to
accept or deny the request and sent a response back.
The protocol is the latest generation of TACACS. TACACS is a simple UDP based
access control protocol originally developed by BBN for the MILNET (Military Network).
XTACACS is now replaced by . is a TCP based access control protocol.
TCP offers a reliable connection-oriented transport, while UDP offers best-effort delivery.
improves on TACACS and XTACACS by separating the functions of authentication,
authorization and accounting and by encrypting all traffic between the Network Access
Server (NAS) and the clients or services or daemon. It allows for arbitrary length
and content authentication exchanges, which allows any authentication mechanism to be
utilized with clients. The protocol allows the client to request very fine-
grained access control by responding to each component of a request.
The MultiLink switch implements a client.
1.
servers and daemons use TCP port 49 for listening to client requests.
Clients connect to this port to send authentication and authorization packets.
2.
There can be more than one server on the network. The MultiLink
Switch Software supports a maximum of five servers.
Summary of Contents for Multilink ML3000
Page 8: ...0 8 MULTILINK ML3000 ETHERNET COMMUNICATIONS SWITCH INSTRUCTION MANUAL CHAPTER 0 ...
Page 274: ...16 14 MULTILINK ML3000 ETHERNET COMMUNICATIONS SWITCH INSTRUCTION MANUAL SNMP CHAPTER 16 SNMP ...
Page 290: ...17 14 MULTILINK ML3000 ETHERNET COMMUNICATIONS SWITCH INSTRUCTION MANUAL LACP CHAPTER 17 LACP ...