10
MDS P-60/P-60 HL Reference Manual
MDS 05-2818A01, Rev. C
Programming and Diagnostics
Transceiver programming and diagnostics are performed by connecting an
MDS Hand-Held Terminal (HHT) or PC running MDS software. With MDS
P-60
models, an HHT can be plugged directly into the packaged system’s Inter-
face/Utility Board. This eliminates the need for unplugging the data cable from
the transceiver’s
INTERFACE
connector. Instructions for connecting a diag-
nostic terminal are given in
Section 4.0 P-60/P-50 Operation on Page 39
.
Packaged System Specifications*
* Specifications are subject to change without notice. For radio specifications, refer
to the associated transceiver instruction manual.
Enclosure Dimensions:
(excluding hardware)
MDS P-60:
13.75 inches H x 11.85 inches W x 6.5 inches D
(35 x 30.1 x 16.5 cm)
MDS P-50:
19.5 inches H x 17.5 inches W x 9.5 inches D
(49.5 x 44.5 x 24.1 cm)
Approximate Weight:
(with backup battery)
MDS P-60:
21 lb. (9.53 kg)
MDS P-50:
33 lb. (15 kg)
Enclosure Impact Resistance:
Tested to 6.78 Joule (5 ft./lb.)
Transceiver types used in packaged systems:
MDS x710 Series, MDS x810 Series, MDS
2300/4300/9300 Series, MDS iNET, MDS
TransNET, Mercury, and others
Temperature Range:
Full performance: –30°C to +60°C
(Reduced battery life at cold temperatures)
Humidity:
95% at + 40°C Non-Condensing
Primary Power Options:
12, 24, 48, 120 Vdc
120–220 Vac
Typical Supply Current:
(Excluding battery-charging current)
Transmit: 1.8 A @ 5 watts
1.0 A @ 1 watt
Receive: 80 mA maximum
Standby (transceiver in “sleep” mode): <15 mA
Backup Power Provision:
(Standard on AC-powered models.)
12 volt battery
4.6 Ah for P-60 series, 5 Ah for P-50 series
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx