28
MDS P-60/P-60 HL Reference Manual
MDS 05-2818A01, Rev. C
Invisible place holder
Figure 13. Typical Wall Mount Installation (MDS P-50)
Pole Mounting Instructions
Standard pole mounting requires the use of
two
pole-mount adapters (P/N
82-1743A01). These brackets must first be bolted to the MDS
P-50 enclosure.
The complete assembly can then be mounted to a wooden utility pole with two
lag screws
or
with two long bolts that extend through the pole. (Threaded rod
can also be used for through-the-pole mounting.) In either case, it is important
to use flat washers with the attaching hardware (fasteners are not supplied).
To pole mount the unit, follow these instructions:
1. Attach the two pole mount adapter brackets to the MDS
P-50
enclosure with suitable nut and bolt assemblies, as shown in
Figure 14 on Page 29
.
2. With the help of an assistant, position the MDS
P-50 enclosure on the pole
at the desired mounting point.
3. Install the attaching hardware (with flat washers) in the center hole of the
two brackets.
4. Tighten the fasteners securely, but do not over-tighten.
TO PRIMARY POWER
(CONDUIT)
COAXIAL CABLE
TO ANTENNA
LAG SCREW
FLAT WASHER
TO DATA EQUIPMENT (RTU)
(4 REQD)
RSPSupply - 1-888-532-2706 - www.RSPSupply.com