42
MDS P-60/P-60 HL Reference Manual
MDS 05-2818A01, Rev. C
Operational Test
To test for proper backup battery operation, proceed as follows:
1. Apply AC power to the packaged system and operate the radio in
the normal manner.
2. When the battery has charged, disconnect the AC power and verify that the
system continues to operate on battery power.
3. Re-apply AC power. This completes the checkout procedure.
4.3 Interface/Utility Board Features and Indicators
Most user interaction with the packaged system takes place at the Inter-
face/Utility Board located in the lower left hand side of the enclosure.
Depending on the model of the unit, a variety of features are available on this
board that will assist you in monitoring and controlling the operation of the
system.
Table 7 on page 42
contains a summary of the available features and
indicators on each packaged model.
Invisible place holder
Table 7. Interface/Utility Board Features & Indicators
Model
Configuration
Order
Wire
Jack
1
HHT Jack
LED
Indicator(s)
Test
Switch
1
Adjustments
2
MDS
P-60
w/Analog
Interface/Utility
Board
J1
(Modular)
J3 (Modular)
CR6—AC
power failure
indicator. (On
with battery
operation.)
CR10—
Transmitter
keyed
SW1—Red
button.
Used to
manually
key the
transceiver.
R9—TX audio
level
R10—RX audio
level
R28—Order wire
deviation
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx