49-2000738 Rev. 0
13
INST
ALLA
TION INSTRUCTIONS
Installation Instructions
FOR YOUR SAFETY
•
)RU3HUVRQDO6DIHW\UHPRYHKRXVHIXVHRURSHQ
circuit breaker before beginning installation.
Failure to do so could result in serious injury or
death.
•
%HVXUH\RXUFRRNWRSLVLQVWDOOHGSURSHUO\E\D
qualified installer or service technician.
•
To eliminate the risk of burns or fire due to
reaching over heated surface elements, cabinet
storage located above the surface units should
be avoided. If cabinet storage space is to be
provided, the risk can be reduced by installing a
range hood that projects horizontally a minimum
RIƎEH\RQGWKHERWWRPRIWKHFDELQHWV&DELQHW
installation above the cooktop may be no deeper
WKDQƎ
•
Make sure the cabinets and wall coverings around
the cooktop can withstand the temperatures (up to
200°F) generated by the cooktop.
•
The cooktop should be easy to reach and lighted
with natural light during the day.
•
Always disconnect the electrical service to the
cooktop before repairing or servicing the cooktop.
This can be done by disconnecting the fuse or
circuit breaker. Failure to do this could result in a
dangerous or fatal shock. Know where your main
disconnect switch is located. If you do not know,
have your electrician show you.
ELECTRICAL REQUIREMENTS
This appliance must be supplied with the proper
voltage and frequency, and connected to an
individual, properly grounded branch circuit,
protected by a circuit breaker or a time delay fuse
as noted on name plate.
We recommend you have the electrical wiring and
hookup of your cooktop connected by a qualified
electrician. After installation, have the electrician
show you where your main cooktop disconnect is
located.
:LULQJPXVWFRQIRUPWR1DWLRQDO(OHFWULFDO&RGH
<RXFDQJHWDFRS\RIWKH1DWLRQDO(OHFWULFDO&RGH
$16,1)3$1R/DWHVW(GLWLRQE\ZULWLQJ
1DWLRQDO)LUH3URWHFWLRQ$VVRFLDWLRQ
%DWWHU\PDUFK3DUN
Quincy, MA 02269
In Canada, wiring must conform to the Canadian
Electrical Code (CEC).
The cooktop conduit wiring is approved for copper
wire connection only, and if you have aluminum
KRXVHZLULQJ\RXPXVWXVHVSHFLDO8/DSSURYHG
connectors for joining copper to aluminum. In
Canada, you must use special CSA approved
connectors for joining copper to aluminum.
<RXPXVWXVHDWZRZLUHWKUHHFRQGXFWRU
VAC, 60 Hertz electrical system. A white (neutral)
wire is not needed for this unit. The cooktop must be
installed in a circuit that does not exceed 125 VAC
nominal to ground.
Refer to the name plate on your cooktop for the KW
rating for your cooktop.
1DPHSODWHORFDWLRQ
KW Rating 240v
KW Rating
208V
Recommended
Circuit Size
'HGLFDWHG
.:
.:
20 Amp
.:.:
4.2 KW - 6.2 KW
30 Amp
.:.:
6.3 KW - 8.3 KW
40 Amp
.:.:
8.4 KW - 10.4
KW
50 Amp