background image

 

 

© 2003 GE Interlogix B.V.  

1045037 

 

All Rights Reserved 

07/2003 

    

  

  

  

  

  

  

  

  

  

 

 

4/8-Zone DGP

  

 

M

OUNTING THE UNIT

 

T

T

h

h

e

e

 

 

P

P

C

C

B

B

 

 

c

c

a

a

n

n

 

 

b

b

e

e

 

 

m

m

o

o

u

u

n

n

t

t

e

e

d

d

 

 

i

i

n

n

 

 

a

a

n

n

y

y

 

 

e

e

x

x

i

i

s

s

t

t

i

i

n

n

g

g

 

 

A

A

T

T

S

S

 

 

s

s

e

e

r

r

i

i

e

e

s

s

 

 

e

e

n

n

c

c

l

l

o

o

s

s

u

u

r

r

e

e

 

 

t

t

h

h

a

a

t

t

 

 

s

s

u

u

p

p

p

p

o

o

r

r

t

t

s

s

 

 

t

t

h

h

e

e

 

 

B

B

B

B

 

 

f

f

o

o

r

r

m

m

a

a

t

t

.

.

 

 

Connections  

J1 

COMMS 

12 VDC power supply. It is recommended that where 
the distance between an ATS1220 and the nearest 
device is more than 100 meters, a separate power 
supply be used. 

COMMS 

Positive and negative data connection of the system 
databus.  

Units can be up to 1.5 km from the 

4-lift DGP or the ATS control panel, depending on 
the cable used. See the ATS control panel 
installation guide for details. 

TAMP 

Connect the enclosure tamper switch across these 
terminals  

(Tamper switch requires normally 

open contacts.) 

J2/J3 

E

E

a

a

c

c

h

h

 

 

z

z

o

o

n

n

e

e

s

s

 

 

r

r

e

e

q

q

u

u

i

i

r

r

e

e

s

s

 

 

a

a

 

 

4

4

k

k

7

7

 

 

e

e

n

n

d

d

-

-

o

o

f

f

-

-

l

l

i

i

n

n

e

e

 

 

r

r

e

e

s

s

i

i

s

s

t

t

o

o

r

r

 

 

(

(

1

1

 

 

o

o

r

r

 

 

2

2

 

 

d

d

e

e

p

p

e

e

n

n

d

d

i

i

n

n

g

g

 

 

o

o

n

n

 

 

s

s

i

i

n

n

g

g

l

l

e

e

 

 

o

o

r

r

 

 

d

d

u

u

a

a

l

l

 

 

z

z

o

o

n

n

e

e

 

 

m

m

o

o

n

n

i

i

t

t

o

o

r

r

i

i

n

n

g

g

 

 

p

p

r

r

o

o

g

g

r

r

a

a

m

m

m

m

e

e

d

d

 

 

i

i

n

n

 

 

A

A

T

T

S

S

 

 

c

c

o

o

n

n

t

t

r

r

o

o

l

l

 

 

p

p

a

a

n

n

e

e

l

l

)

)

.

.

 

 

J4 

+

+

1

1

2

2

 

 

V

V

D

D

C

C

 

 

s

s

u

u

p

p

p

p

l

l

y

y

 

 

a

a

n

n

d

d

 

 

o

o

p

p

e

e

n

n

 

 

c

c

o

o

l

l

l

l

e

e

c

c

t

t

o

o

r

r

 

 

o

o

r

r

 

 

d

d

a

a

t

t

a

a

 

 

o

o

u

u

t

t

p

p

u

u

t

t

 

 

f

f

o

o

r

r

 

 

o

o

u

u

t

t

p

p

u

u

t

t

 

 

c

c

o

o

n

n

n

n

e

e

c

c

t

t

i

i

o

o

n

n

 

 

t

t

o

o

 

 

A

A

T

T

S

S

 

 

1

1

8

8

1

1

0

0

,

,

 

 

A

A

T

T

S

S

 

 

1

1

8

8

1

1

1

1

 

 

a

a

n

n

d

d

 

 

A

A

T

T

S

S

 

 

1

1

8

8

2

2

0

0

 

 

o

o

u

u

t

t

p

p

u

u

t

t

 

 

c

c

a

a

r

r

d

d

s

s

 

 

v

v

i

i

a

a

 

 

1

1

0

0

-

-

w

w

a

a

y

y

 

 

c

c

a

a

b

b

l

l

e

e

 

 

s

s

u

u

p

p

p

p

l

l

i

i

e

e

d

d

 

 

w

w

i

i

t

t

h

h

 

 

t

t

h

h

e

e

 

 

o

o

u

u

t

t

p

p

u

u

t

t

 

 

c

c

a

a

r

r

d

d

.

.

 

 

U

U

p

p

 

 

t

t

o

o

 

 

s

s

i

i

x

x

t

t

e

e

e

e

n

n

 

 

o

o

u

u

t

t

p

p

u

u

t

t

s

s

 

 

a

a

r

r

e

e

 

 

a

a

v

v

a

a

i

i

l

l

a

a

b

b

l

l

e

e

 

 

w

w

i

i

t

t

h

h

 

 

8

8

-

-

w

w

a

a

y

y

 

 

o

o

r

r

 

 

1

1

6

6

-

-

w

w

a

a

y

y

 

 

o

o

p

p

e

e

n

n

 

 

c

c

o

o

l

l

l

l

e

e

c

c

t

t

o

o

r

r

 

 

c

c

a

a

r

r

d

d

s

s

 

 

(

(

4

4

-

-

w

w

a

a

y

y

 

 

a

a

n

n

d

d

 

 

8

8

/

/

1

1

6

6

-

-

w

w

a

a

y

y

 

 

o

o

u

u

t

t

p

p

u

u

t

t

 

 

c

c

a

a

r

r

d

d

s

s

 

 

c

c

a

a

n

n

n

n

o

o

t

t

 

 

b

b

e

e

 

 

u

u

s

s

e

e

d

d

 

 

t

t

o

o

g

g

e

e

t

t

h

h

e

e

r

r

 

 

o

o

n

n

 

 

t

t

h

h

e

e

 

 

s

s

a

a

m

m

e

e

 

 

D

D

G

G

P

P

)

)

 

 

L

INKS

 

 

Earth connection. Earth wires from all pieces of 
equipment must be earthed at one system earth. For 
further detail see the ATS control panel installation 
guide. 

“I

NT

./E

XT

. T

AMP

” J

UMPER 

S

ETTINGS 

}

 

INT 

Tamper switch SW4 + switch on backside SW5 of 
the PCB are used (eg. in combination with ATS1644, 
plastic housing). 

EXT 

Tamper connections on connector J1 (T,,C) are used 
for an external tamper switch (eg. In combination 
with ATS1643, metal housing).  

DGP 

DIPSWITCH SETTINGS 

 

ADDR 

{

 

Dip switches 1 to 4 are used to identify the DGP 
number. 

ABCT 

|

 

 

Set switch T on if this device is the last device on the 
system databus. For more details see the ATS 
control panel installation guide. 

A,C 

Not in use 

ON - ATS1811 8-way relay card or ATS1820 16-way 
open collector card connected to J4. 
OFF - no ATS1811 or ATS1820 connected to J4. 
Use this setting also if an ATS1810 is connected to 
J4.  

Z

ONE NUMBERING

 

A

A

 

 

4

4

/

/

8

8

-

-

z

z

o

o

n

n

e

e

s

s

 

 

D

D

G

G

P

P

 

 

c

c

a

a

n

n

 

 

h

h

a

a

v

v

e

e

 

 

f

f

o

o

u

u

r

r

 

 

o

o

r

r

 

 

e

e

i

i

g

g

h

h

t

t

 

 

z

z

o

o

n

n

e

e

s

s

 

 

c

c

o

o

n

n

n

n

e

e

c

c

t

t

e

e

d

d

 

 

t

t

o

o

 

 

i

i

t

t

.

.

 

 

T

T

h

h

e

e

r

r

e

e

 

 

a

a

r

r

e

e

 

 

1

1

6

6

 

 

z

z

o

o

n

n

e

e

s

s

 

 

a

a

l

l

l

l

o

o

c

c

a

a

t

t

e

e

d

d

 

 

t

t

o

o

 

 

e

e

v

v

e

e

r

r

y

y

 

 

D

D

G

G

P

P

 

 

a

a

d

d

d

d

r

r

e

e

s

s

s

s

.

.

 

 

O

O

n

n

l

l

y

y

 

 

z

z

o

o

n

n

e

e

s

s

 

 

1

1

 

 

t

t

o

o

 

 

4

4

 

 

o

o

r

r

 

 

1

1

 

 

t

t

o

o

 

 

8

8

 

 

c

c

a

a

n

n

 

 

b

b

e

e

 

 

u

u

s

s

e

e

d

d

 

 

w

w

h

h

e

e

n

n

 

 

a

a

n

n

 

 

A

A

T

T

S

S

1

1

2

2

1

1

0

0

/

/

1

1

2

2

1

1

1

1

/

/

1

1

2

2

2

2

0

0

 

 

i

i

s

s

 

 

a

a

l

l

l

l

o

o

c

c

a

a

t

t

e

e

d

d

 

 

a

a

 

 

D

D

G

G

P

P

 

 

n

n

u

u

m

m

b

b

e

e

r

r

.

.

 

 

Z

Z

o

o

n

n

e

e

s

s

 

 

n

n

o

o

t

t

 

 

a

a

v

v

a

a

i

i

l

l

a

a

b

b

l

l

e

e

 

 

(

(

5

5

 

 

-

-

 

 

1

1

6

6

)

)

 

 

o

o

r

r

 

 

(

(

8

8

-

-

1

1

6

6

)

)

 

 

s

s

h

h

o

o

u

u

l

l

d

d

 

 

b

b

e

e

 

 

p

p

r

r

o

o

g

g

r

r

a

a

m

m

m

m

e

e

d

d

 

 

a

a

s

s

 

 

t

t

y

y

p

p

e

e

 

 

0

0

 

 

(

(

z

z

o

o

n

n

e

e

 

 

d

d

i

i

s

s

a

a

b

b

l

l

e

e

d

d

)

)

 

 

i

i

n

n

 

 

t

t

h

h

e

e

 

 

Z

Z

o

o

n

n

e

e

 

 

d

d

a

a

t

t

a

a

b

b

a

a

s

s

e

e

.

.

 

 

C

C

o

o

n

n

t

t

r

r

o

o

l

l

 

 

p

p

a

a

n

n

e

e

l

l

 

 

1

1

 

 

 

 

1

1

6

6

 

 

D

D

G

G

P

P

8

8

 

 

1

1

2

2

9

9

 

 

-

-

 

 

1

1

4

4

4

4

 

 

D

D

G

G

P

P

1

1

 

 

1

1

7

7

 

 

-

-

 

 

3

3

2

2

 

 

D

D

G

G

P

P

9

9

 

 

 

 

1

1

4

4

5

5

 

 

-

-

 

 

1

1

6

6

0

0

 

 

D

D

G

G

P

P

2

2

 

 

3

3

3

3

 

 

-

-

 

 

4

4

8

8

 

 

D

D

G

G

P

P

1

1

0

0

 

 

 

 

1

1

6

6

1

1

 

 

-

-

 

 

1

1

7

7

6

6

 

 

D

D

G

G

P

P

3

3

 

 

4

4

9

9

 

 

-

-

 

 

6

6

4

4

 

 

D

D

G

G

P

P

1

1

1

1

 

 

 

 

1

1

7

7

7

7

 

 

-

-

 

 

1

1

9

9

2

2

 

 

D

D

G

G

P

P

4

4

 

 

6

6

5

5

 

 

-

-

 

 

8

8

0

0

 

 

D

D

G

G

P

P

1

1

2

2

 

 

 

 

1

1

9

9

3

3

 

 

-

-

 

 

2

2

0

0

8

8

 

 

D

D

G

G

P

P

5

5

 

 

8

8

1

1

 

 

-

-

 

 

9

9

6

6

 

 

D

D

G

G

P

P

1

1

3

3

 

 

 

 

2

2

0

0

9

9

 

 

-

-

 

 

2

2

2

2

4

4

 

 

D

D

G

G

P

P

6

6

 

 

9

9

7

7

 

 

-

-

 

 

1

1

1

1

2

2

 

 

D

D

G

G

P

P

1

1

4

4

 

 

 

 

2

2

2

2

5

5

 

 

-

-

 

 

2

2

4

4

0

0

 

 

D

D

G

G

P

P

7

7

 

 

1

1

1

1

3

3

 

 

-

-

 

 

1

1

2

2

8

8

 

 

D

D

G

G

P

P

1

1

5

5

 

 

 

 

2

2

4

4

1

1

 

 

-

-

 

 

2

2

5

5

6

6

 

 

N

N

o

o

t

t

e

e

 

 

1

1

:

:

 

 

T

T

h

h

e

e

 

 

A

A

T

T

S

S

1

1

2

2

1

1

0

0

/

/

1

1

2

2

1

1

1

1

/

/

1

1

2

2

2

2

0

0

 

 

c

c

a

a

n

n

n

n

o

o

t

t

 

 

b

b

e

e

 

 

e

e

x

x

p

p

a

a

n

n

d

d

e

e

d

d

 

 

t

t

o

o

 

 

p

p

r

r

o

o

v

v

i

i

d

d

e

e

 

 

a

a

d

d

d

d

i

i

t

t

i

i

o

o

n

n

a

a

l

l

 

 

z

z

o

o

n

n

e

e

s

s

.

.

 

 

LED’

S

 

RX  LED flashes to indicate polling data is being received on the 

system databus from the ATS control panel. If the LED does 
not flash the control panel is not operational or the databus is 
faulty (usually cabling). 

TX  LED flashes to indicate the DGP is replying to polling from the 

ATS control panel. If the RX  LED flashes but the TX LED 
does not, it indicates that the DGP is not programmed to be 
polled in the control panel or that it is addressed incorrectly. 


D+ 
D- 

T

ATS1210/1211/1220 

4/8-Zone DGP

Summary of Contents for Interlogix ARITECH ATS1210

Page 1: ...nector J1 T C are used for an external tamper switch eg In combination with ATS1643 metal housing DGP DIPSWITCH SETTINGS ADDR Dip switches 1 to 4 are used to identify the DGP number ABCT T Set switch T on if this device is the last device on the system databus For more details see the ATS control panel installation guide A C Not in use B ON ATS1811 8 way relay card or ATS1820 16 way open collector...

Page 2: ...t ê êt tr re e p pr ro og gr ra am mm mé ée es s c co om mm me e é ét ta an nt t d de e t ty yp pe e 0 0 z zo on ne e d dé és sa ac ct ti iv vé ée e d da an ns s l la a b ba as se e d de e d do on nn né ée es s Z Zo on ne e C Ce en nt tr ra al le e 1 1 à à 1 16 6 D DG GP P8 8 1 12 29 9 à à 1 14 44 4 D DG GP P1 1 1 17 7 à à 3 32 2 D DG GP P9 9 1 14 45 5 à à 1 16 60 0 D DG GP P2 2 3 33 3 à à 4 48 8 ...

Page 3: ...ono trovarsi sino a 1 5 km di distanza dal concentratore per 4 ascensori o dalla centrale ATS a seconda del cavo usato Per ulteriori informazioni fare riferimento alla guida di installazione della centrale ATS TAMP Collegare l interruttore antimanomissione del contenitore su questi terminali l interruttore antimanomissione richiede contatti normalmente aperti J2 J3 Ogni zona richiede 1 o 2 resisto...

Page 4: ...zenia z kartami wyjść ATS1810 ATS1811 i ATS1820 za pośrednictwem 10 żyłowego kabla dostarczonego wraz z kartą wyjść Na karcie z 8 lub 16 wyjściami typu OC otwarty kolektor dostępnych jest do szesnastu wyjść karty wyjść z 4 wyjściami i karty z 8 16 wyjściami nie mogą być używane razem w tym samym module MZD ZWORY Połączenie uziemienia Przewody uziemiające ze wszystkich części urządzenia muszą być u...

Page 5: ... N Nã ão o e es st tá á a a s se er r u ut ti il li iz za ad do o B ON Carta de relay de 8 vias ATS1811 ou carta de colector aberto ATS1820 de 16 vias ligada a J4 OFF nenhum ATS1811 ou ATS1820 ligado a J4 Utilize esta configuração se houver também um ATS1810 ligado ao J4 NUMERAÇÃO DE ZONAS U Um m D DG GP P d de e 4 4 8 8 z zo on na as s p po od de e t te er r q qu ua at tr ro o o ou u o oi it to o...

Page 6: ...l D DG GP P d de e 4 4 8 8 z zo on na as s e en n c cu ua al lq qu ui ie er r c ca aj ja a d de e l la a s se er ri ie e A AT TS S c co om mp pa at ti ib bl le e c co on n e el l f fo or rm ma at to o B BB B CONEXIONES J1 COMMS Salida de alimentación de 12 V CC Es recomendable utilizar una fuente de alimentación independiente cuando la distancia entre una unidad ATS1220 y el dispositivo más cercan...

Page 7: ...T SAB JUMPER INDSTILLINGE Med jumper i INT er sabotagekontakter på print aktive SW4 mod låg og SW 5 mod væg Print i ATS 1644 plastkabinet Med jumper i EXT benyttes ekstern sabotagekontakt tilsluttet i J1 T C print i ATS 1643 metalkabinet LINKS Jordtilslutning Jordledninger fra alle udstyrsdele skal samles i en fælles jordledning Du finder yderligere oplysninger i installationsmanualen til ATS cent...

Page 8: ... å åt tt ta a s se ek kt ti io on ne er r a an ns sl lu ut tn na a V Va ar rj je e D DG GP P a ad dr re es ss s t ti il ll ld de el la as s 1 16 6 s se ek kt ti io on ne er r E En nd da as st t s se ek kt ti io on ne er rn na a 1 1 t ti il ll l 4 4 e el ll le er r 1 1 t ti il ll l 8 8 k ka an n a an nv vä än nd da as s n nä är r e en n A AT TS S1 12 21 10 0 1 12 21 11 1 1 12 22 20 0 t ti il ll ld ...

Page 9: ...9 ...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...s ss sp pe en nn ni in ng g T Te en ns si ió ón n d de e a al li im me en nt ta ac ci ió ón n 1 10 0 5 5 1 13 3 8 8 V V P Po ob bó ór r p pr rą ąd du u C Co on ns su um mo o d de e c co or rr re en nt te e S St tr rø øm mf fo or rb br ru uk k C Co on ns su um mo o d de e c co or rr ri ie en nt te e 5 53 3 m mA A m ma ax x W Wy ym mi ia ar ry y W W x x S S p pł ły yt tk ka a d dr ru uk ko ow wa an ...

Reviews: