background image

5

  

WARNING:

 

Emergency Bypass 

If System is equipped with a Bypass Valve, do not 

open Bypass Valve except in emergencies. Opening 

the Bypass Valve will permit potentially microbially 

contaminated water to enter the household water 

distribution system. Drinking contaminated water may 

cause serious illness and/or death. Do not drink the 

water if the System has been operated in bypass mode. 
If the System has been operated in bypass mode and 

if the water is being drawn from a well or surface 

water source, the System and the household water 

distribution system should be disinfected again once 

returned to filtration mode.
If the System is in bypass mode, the Controller must be 

unplugged. Failure to do so may cause System to dry 

and become damaged, leading to personal injury, and/

or physical damage and will void all warranties.
A bypass is not required for proper operation of the 

System. However, some local plumbing codes may 

require a bypass. If a bypass is to be installed, the 

procedure described below is to be followed in order 

to provide water in an emergency or during System 

malfunction.

Bypass Procedure

1. 

Close Inlet and Outlet Valves. (If ball valves are 

installed, turn the handles perpendicular to the 

water pipe.)

2. 

Open Bypass Valve (If ball valve is installed, turn 

the handle in-line with the water pipe).

3. 

Unplug Controller.

To return to filtered water service:

1. 

Close Bypass Valve. (If ball valve is installed, turn 

the handle perpendicular to the water pipe.)

2. 

Open Inlet and Outlet Valves. (If ball valves are 

installed, turn the handles in-line with the water 

pipe.)

3. 

Plug in the Controller.

4. 

Follow the System Membrane Cleaning section 

under E. MAINTENANCE SCHEDULE in this manual 

to re-commission the System.

C. CERTIFICATION

Current System Certifications, as well as the limits to those 

certifications held, are listed below. 
The System should only be installed where it complies with 

provincial, state or municipal laws and regulations. 
The System should only be used to filter cold supply water.

BioVir Laboratories

NELAP* and California Department of Health accredited 

laboratory
*National Environmental Laboratory Accreditation 

Program (NELAP) Accredited #05234CA
The Homespring UF200 Series Water Purifiers have 

been tested by BioVir Laboratories Inc. and found 

to meet all the requirements of the USEPA’s Guide 

Standard and Protocol for Testing Microbiological Water 

Purifiers (OPP Task Force Report, 1987) as interpreted by 

the BioVir Laboratories specifically for the Homespring 

UF200 Series Products.
The test results were:

 

**Bacteria Reduction: >99.99999%

 

***Virus Reduction: >99.999%
*National Environmental Laboratory Accrediation 

Committee (NELAC) Accredited #05234CA

 

**Tested with E.coli bacteria

 

***Tested with MS2 Coliphage

Water Quality Association

The Homespring UF200 Series Water Purifiers have 

been Tested and Certified by the Water Quality 

Association (WQA) to the USEPA’s Guide Standard and 

Protocol for Testing Microbiological Water Purifiers (OPP 

Task Force Report, 1987) as interpreted by the WQA and 

to NSF/ANSI 42 and 53.

TE

ST

ED

AND CERTIF

IED

U

N

D

ER

IND

USTRY STA

ND

A

RD

S

Summary of Contents for Homespring

Page 1: ...1 HomespringTM by GE Water Purifier System Owners Manual...

Page 2: ...CTION 3 B SAFETY WARNINGS 4 5 C CERTIFICATION 5 D OPERATIONS 6 8 E MAINTENANCE SCHEDULE 9 11 F WINTERIZATION 12 15 G TROUBLESHOOTING 15 16 H REPLACEMENT PART LIST AND PROCEDURES 17 21 I SPECIFICATIONS...

Page 3: ...asic principles of household water collection treatment and discharge and some of the features of the Homespring Water Purifier System It is not intended to be a definitive dissertation on the princip...

Page 4: ...rvice provided it is installed commissioned operated maintained and tested in strict accordance to the safety instructions contained in this manual Failure to properly maintain the System will comprom...

Page 5: ...lar to the water pipe 2 Open Inlet and Outlet Valves If ball valves are installed turn the handles in line with the water pipe 3 Plug in the Controller 4 Follow the System Membrane Cleaning section un...

Page 6: ...cial attention under normal operating conditions The System uses existing water pressure in the water supply line to filter water and will continue to operate even during a power failure Electricity i...

Page 7: ...Kit is installed select either Program 3 or Program 4 in this application Water Clarity Advanced Plus Controller Low Turbidity Less than 0 5 NTU Program 1 Medium Turbidity Peaks to 1 0 NTU less than 7...

Page 8: ...utton is held down for 5 seconds the Drain Solenoid Valve will remain open for 5 minutes To interrupt flushing press MANUAL FLUSH again The Drain Solenoid Valve will be closed automatically after 5 mi...

Page 9: ...be performed every 12 months unless specified otherwise Refer to H REPLACEMENT PART LIST AND PROCEDURES for part numbers System Part Annual Maintenance Tasks UFC 211 UF 211 Carbon Prefilter Replace W...

Page 10: ...tire procedure to avoid contaminated water entering the household distribution system Contaminated water might cause personal injury and in some cases death This cleaning procedure does NOT disinfect...

Page 11: ...ath Replace the System Cap Vertical Systems or the Brass Plug Horizontally mounted Systems Let stand for 60 minutes Annual Maintenance Check Summary The Homespring Authorized Technician performs the f...

Page 12: ...etely drain the System and household piping To drain the System refer to the Controller Functions section under D OPERATIONS on how to perform a Manual Flush To drain the household pipes open a cold w...

Page 13: ...vity FIGURE 13 7 If a Stainless Steel Prefilter has been set aside place the Stainless Steel Prefilter in the Prefilter cavity 8 For all Sytems replace the System Cap using the Cap Wrench and check bo...

Page 14: ...ssary Add 2 cups 500 ml of unscented household bleach 5 6 chlorine or 1 cup 250 ml chlorine bleach 12 chlorine maximum 3 months old to the System 8 Allow the System to soak for 15 minutes With the Sys...

Page 15: ...ace is clean and is intact Ensure connections are tight Contact your Dealer System water flow is noticeably reduced Check if Thimble Filter is clogged Depressurize System remove System Cap and Interna...

Page 16: ...unctions section under D OPERATIONS on how to perform a manual flush sequence and ensure button on controller is pressed for a full 5 seconds A buzz sound should be heard from the Drain Solenoid Valve...

Page 17: ...remove the System Cap 4 Put on a pair of disposable gloves and carefully remove and dispose of the Internal Prefilter Check that the Thimble Filter is in place seated in the spigot DO NOT attempt to...

Page 18: ...18 UFC 211 and UF 211 Series FIGURE 20 24 13 6 10 3 5 11 1 2 17 18 20 19 21 16 4 3 7 8 22 23 14 15 12 9...

Page 19: ...3024987 Cap Wrench UF 211 X 14 Backpulse Tank X 15 3035560 Controller Power Supply DC X Sub Assembly Kits 16 3025172 Installation Sub Assembly Kit Base shims anchors Mini Ball Valves with Plugs 2 Nylo...

Page 20: ...4 FNPT Flapper X 6 3025096 Brass Nipple 3 4 X 7 3030405 External Prefilter Housing and Head X 8 3025174 Wall Bracket Kit Filter Housing X 9 3025371 Mini Ball Valve Plug 1 4 X 10 3024982 Mini Ball Val...

Page 21: ...aims are based on a continuous flow of 4 5 gpm 17 Lpm 2 Pressure drops are given for systems when they are new and equipped as specified by the model number At temperatures below 77 F 25 C the pressur...

Page 22: ...nside the dwelling will be significantly reduced during System cleaning Flushing Flushing includes a Front flush and a Back flush Systems that are installed in municipal cistern or ground water source...

Page 23: ...een a water quality issue such as a recent boil water alert or water main break from the municipal water source the household pipes should be sanitized upon installation of the System How long does th...

Page 24: ...ling the System excluding the attached parts will need to be replaced Will the System remove iron sulfur The pore size of the membrane is 0 02 microns nominal which may help in the filtration of parti...