E. MAINTENANCE SCHEDULE 

  

WARNING: 

The System has been 

designed and tested to offer reliable service, provided if 

it is installed, commissioned, operated, maintained and 

tested in strict accordance to the safety instructions 

contained in this manual. Failure to properly maintain 

the System will compromise performance and/or 

result in failure to control water quality which may 

lead to delivery of contaminated water. Consuming 

contaminated water could result in serious injury or 

possible death.

A Homespring Authorized Technician must perform all service 

and maintenance. As part of the annual maintenance, the 

Homespring Authorized Technician will perform an Integrity 

Test to check the condition of the System membrane and 

perform a cleaning procedure to clean the System membrane. 

This annual test and cleaning is mandatory as part of the 

5-year limited prorated membrane warranty.
If the Homespring Authorized Technician determines that 

the System has a high degree of debris and contaminants, 

causing an abnormally high reduction in System flowrate, 

the number of maintenance visits per year may be increased 

to ensure that the System functions within its acceptable 

operational parameters and to ensure that the limited 

warranty remains in effect.

Maintenance Schedule 

The following maintenance tasks must be performed every 12 

months unless specified otherwise. Refer to:

 

H. REPLACEMENT PART LIST AND PROCEDURES for part numbers.

System Part

Annual Maintenance Tasks

UFC 211

UF 211

Carbon 

Prefilter

Replace. Water sources with 

high level of particulate and/

or chlorine will require more 

frequent replacement.

X

n/a

Stainless Steel 

Prefilter

Clean. Water sources with 

high level of sediment will 

require more frequent 

cleaning.

n/a

X

System 

Membrane

Clean

X

X

System 

Membrane

Perform Integrity Test

X

X

Backpulse 

Tank Air 

Pressure

Check and adjust

X

X

Controller 

Batteries  

(2 AA)

Replace

X

X

Controller 

Flushing and 

Draining 

programs

Verify if settings are still 

appropriate

X

X

Every 6 Months: For models equipped with the Surface Water 

Option Kit, the External Prefilter cartridge must be inspected, 

cleaned and/or replaced. 

System Membrane Cleaning 

The following System cleaning procedures are performed 

by the Homespring Authorized Technician during the annual 

maintenance. 

  

WARNING: 

Disposable protective 

gloves must be worn during maintenance of the 

System to protect your hands. At the end of the 

procedure, wash your hands thoroughly with soap and 

water. Do not reuse the gloves. Dispose of the gloves in 

the garbage. 

Ensure that the two Mini Ball Valves are closed (To close, 

turn the handle perpendicular to the Plug/hose end). Remove 

the Plug from the Inlet Mini Ball Valve by depressing the lock 

ring and pulling on the Plug. 

FIGURE 6

The valve is OPEN when handle 

is in the position shown

 Lock Ring

Mini Ball Valve

Summary of Contents for Homespring

Page 1: ...1 HomespringTM by GE Water Purifier System Owners Manual...

Page 2: ...CTION 3 B SAFETY WARNINGS 4 5 C CERTIFICATION 5 D OPERATIONS 6 8 E MAINTENANCE SCHEDULE 9 11 F WINTERIZATION 12 15 G TROUBLESHOOTING 15 16 H REPLACEMENT PART LIST AND PROCEDURES 17 21 I SPECIFICATIONS...

Page 3: ...asic principles of household water collection treatment and discharge and some of the features of the Homespring Water Purifier System It is not intended to be a definitive dissertation on the princip...

Page 4: ...rvice provided it is installed commissioned operated maintained and tested in strict accordance to the safety instructions contained in this manual Failure to properly maintain the System will comprom...

Page 5: ...lar to the water pipe 2 Open Inlet and Outlet Valves If ball valves are installed turn the handles in line with the water pipe 3 Plug in the Controller 4 Follow the System Membrane Cleaning section un...

Page 6: ...cial attention under normal operating conditions The System uses existing water pressure in the water supply line to filter water and will continue to operate even during a power failure Electricity i...

Page 7: ...Kit is installed select either Program 3 or Program 4 in this application Water Clarity Advanced Plus Controller Low Turbidity Less than 0 5 NTU Program 1 Medium Turbidity Peaks to 1 0 NTU less than 7...

Page 8: ...utton is held down for 5 seconds the Drain Solenoid Valve will remain open for 5 minutes To interrupt flushing press MANUAL FLUSH again The Drain Solenoid Valve will be closed automatically after 5 mi...

Page 9: ...be performed every 12 months unless specified otherwise Refer to H REPLACEMENT PART LIST AND PROCEDURES for part numbers System Part Annual Maintenance Tasks UFC 211 UF 211 Carbon Prefilter Replace W...

Page 10: ...tire procedure to avoid contaminated water entering the household distribution system Contaminated water might cause personal injury and in some cases death This cleaning procedure does NOT disinfect...

Page 11: ...ath Replace the System Cap Vertical Systems or the Brass Plug Horizontally mounted Systems Let stand for 60 minutes Annual Maintenance Check Summary The Homespring Authorized Technician performs the f...

Page 12: ...etely drain the System and household piping To drain the System refer to the Controller Functions section under D OPERATIONS on how to perform a Manual Flush To drain the household pipes open a cold w...

Page 13: ...vity FIGURE 13 7 If a Stainless Steel Prefilter has been set aside place the Stainless Steel Prefilter in the Prefilter cavity 8 For all Sytems replace the System Cap using the Cap Wrench and check bo...

Page 14: ...ssary Add 2 cups 500 ml of unscented household bleach 5 6 chlorine or 1 cup 250 ml chlorine bleach 12 chlorine maximum 3 months old to the System 8 Allow the System to soak for 15 minutes With the Sys...

Page 15: ...ace is clean and is intact Ensure connections are tight Contact your Dealer System water flow is noticeably reduced Check if Thimble Filter is clogged Depressurize System remove System Cap and Interna...

Page 16: ...unctions section under D OPERATIONS on how to perform a manual flush sequence and ensure button on controller is pressed for a full 5 seconds A buzz sound should be heard from the Drain Solenoid Valve...

Page 17: ...remove the System Cap 4 Put on a pair of disposable gloves and carefully remove and dispose of the Internal Prefilter Check that the Thimble Filter is in place seated in the spigot DO NOT attempt to...

Page 18: ...18 UFC 211 and UF 211 Series FIGURE 20 24 13 6 10 3 5 11 1 2 17 18 20 19 21 16 4 3 7 8 22 23 14 15 12 9...

Page 19: ...3024987 Cap Wrench UF 211 X 14 Backpulse Tank X 15 3035560 Controller Power Supply DC X Sub Assembly Kits 16 3025172 Installation Sub Assembly Kit Base shims anchors Mini Ball Valves with Plugs 2 Nylo...

Page 20: ...4 FNPT Flapper X 6 3025096 Brass Nipple 3 4 X 7 3030405 External Prefilter Housing and Head X 8 3025174 Wall Bracket Kit Filter Housing X 9 3025371 Mini Ball Valve Plug 1 4 X 10 3024982 Mini Ball Val...

Page 21: ...aims are based on a continuous flow of 4 5 gpm 17 Lpm 2 Pressure drops are given for systems when they are new and equipped as specified by the model number At temperatures below 77 F 25 C the pressur...

Page 22: ...nside the dwelling will be significantly reduced during System cleaning Flushing Flushing includes a Front flush and a Back flush Systems that are installed in municipal cistern or ground water source...

Page 23: ...een a water quality issue such as a recent boil water alert or water main break from the municipal water source the household pipes should be sanitized upon installation of the System How long does th...

Page 24: ...ling the System excluding the attached parts will need to be replaced Will the System remove iron sulfur The pore size of the membrane is 0 02 microns nominal which may help in the filtration of parti...

Reviews: