1)
Press NEXT twice until
“SET TiME”
flashes on
screen. Press ENTER.
2)
Press the UP and DOWN arrows to set the hour.
Press ENTER.
3)
Press the UP and DOWN arrows to set the
minute. Press ENTER.
Setting the Clock
1
FigUre 29
1)
Press NEXT three times until
“STarT TiME”
flashes on screen. Press ENTER.
2)
Press the UP and DOWN arrows to set the hour.
Press ENTER.
3)
Press the UP and DOWN arrows to set the min
ute.
Press ENTER.
Note: Select a time that water usage is not expected in the
dwelling. (e.g. 2:00 a.m.) Check with homeowner.
Setting flush/Drain Time
2
fiGUrE 30
Low Turbidity: Less than 0.5 NTU
Medium Turbidity:
Peaks to 1.0 NTU, less than 72 min.
per day.
High Turbidity:
Peaks to 5.0 NTU, less than 72 min. per
day.
Very High Turbidity:
Peaks to 10.0 NTU, less than 72 min.
per day.
NOTE: If surface water is the source, use either an Ad
-
vanced Controller or an Advanced Plus Controller. Select
either Program 3 or Program 4 in this application.
Setting the Program
Choosing a program:
3
controller settings
1)
Press NEXT four times until
“PrOgrAm”
flashes on screen.
2)
Press ENTER.
3)
Press the UP and DOWN arrows to set the
Program number. Select the appropriate Program
for your application. Press ENTER.
fiGUrE 31
NOTE:
Electrical power to the Controller must be on to
activate the flushing and draining sequences. The batteries
are for keeping the time in case of power failure and will
not activate the flushing and draining sequences.
NOTE:
Once the Controller is set, the Controller will
remember the Start Time, Program Number, and Flush/
Drain Interval settings
(if applicable) even if the electrical
power to the Controller is interrupted.
NOTE:
When the System is undergoing a flushing or a
draining sequence, very little or no water will be available
for use in the dwelling. If possible, select a time for the
flushing and draining when no water generation is required.
Normal operation will resume once the flushing and
draining sequences are finished.
Install the two provided AA batteries in the
Controller. Replace the Controller front cover and
plug the transformer into the electrical receptacle.
6
cleaning
Sequence
duration
Approximate
Water
consumption
per cleaning
Cycle at 7gpm
Base
controller
Program 1
2 flushes
3 minutes
10 US Gal
Program 2
3 flushes
5 minutes
15 US Gal
Program 3
4 flushes
7 minutes
20 US Gal
advanced
controller
and
advanced
Plus
controller
Program 1
2 flushes
2.5 minutes
7.5 US Gal
Program 2
4 flushes
6 minutes
15 US Gal
Program 3
2 flushes
and 1 drain
8.5 minutes
13.5 US Gal
Program 4
2 flushes
and 2 drains
16.5
minutes
19.5 US Gal
Water
Clarity
UFC 207/
UF 207
UFC 100/
UF 100
UFC 209/ UF 209
UFC 211/ UF 211 and UF
100 with optional Surface
Water Option Kit
Low
Turbidity
Program 1
Program 1
Program 1
Medium
Turbidity
Program 2
Program 2
Program 2
High
Turbidity
Program 3
Program 3
Program 3
Very High
Turbidity
not recom-
mended
not applicable
Program 4
16