Setting the flush/Drain interval:
Applicable to the Advanced Plus Controller only.
The Advanced Plus Controller is standard for UFC 207,
UF 207, UFC 209, UF 209, UFC 211, UF 211 models.
4
fiGUrE 32
At the start of the System’s 11
th
month of operation, the yellow
service indicator light will come on. This is an indication that
the System Annual Maintenance is required.
At the System’s 11½
th
month of operation, the yellow service
indicator light will begin to flash and an audible alarm will
start to beep.
To temporarily silence the alarm, depress and hold the UP
and DOWN arrows
together
for three seconds. The alarm
will come back on in seven days after this command is
executed.
To permanently turn the alarm off, depress and hold the UP
and DOWN arrows
together
and press ENTER.
“A oF” (alarm off) will appear on the screen. To turn the alarm
on again, repeat the above step. “A on” (alarm on) will appear
on the screen.
To reset the Controller, press NEXT and ENTER together and
hold for 3 seconds. The yellow light will go off and the green
light will come on again.
Note: Under conditions of turbid water and high usage of the
System, select a Flush/Drain Interval setting appropriate to the
specific application. Increase frequency of flush/drain cycle if
the System TMP rises too quickly. Increasing the number of
Flush/Drain cycles per day will prolong the life of the System;
however, more water will be used for system cleaning purposes.
a. Manual flush
Note: For use when the instructions in this manual or the
Owner’s Manual call for a Manual Flush.
To manually flush the System, press NEXT once.
“ManUal”
flashes on the screen. Press MANUAL FLUSH to open
the Drain Solenoid Valve. If the MANUAL FLUSH button
is held down for 5 seconds, the Drain Solenoid Valve will
remain open for 5 minutes. To interupt flushing, press
MANUAL FLUSH again. The Drain Solenoid Valve will
be closed automatically after 5 minutes if not interrupted.
B. light and alarm function:
Applicable to the Advanced Plus Controller only:
The green light on the controller indicates that the
System is in operation. The green light will be on for
10 months from the first commissioning of the System.
WARNING!
The green light is NOT an indication of the integrity of
the membrane inside the System.
1)
Press NEXT five times until “
t:01
” appears on
screen.
2)
To change the flush/drain interval setting, hold
the UP and DOWN arrows down
together
and
press NEXT. Release all buttons and repeat to
shift to the next interval. There are five interval
settings to choose from:
Controller functions
Surface Water Option Kit installation
In surface water installations, the Homespring™ Qualified
Technician must inform the homeowner and home
occupants that the entire water supply and distribution
system of the dwelling must be disinfected prior to use.
WARNING!