Euro Simon Security System
33
Delete—Option #—68—DONE.
Option 69: SIA Limits (Default = on)*
Determines whether Entry, Exit, and Dialer delay times fall within SIA limits (on) or factory
ranges (off).
The following table shows the available settings when this option is on or off.
Note
If options 10, 11 or 17 are
set outside the SIA limits
while Option 69 is OFF, turn-
ing Option 69 ON will not
affect options 10, 11 or 17,
until they are manually
changed.
¾
To turn on SIA Limits, press:
Add—Option #—69—DONE.
¾
To turn off SIA Limits, press:
Delete—Option #—69—DONE.
Option 70: Line Cut Detection (Default = off)
Determines whether the panel detects and indicates a phone line failure trouble condition
before the programmed time expires (on) or not at all (off).
Important !
This option works cor-
rectly only if the panel
phone line is wired for line
seizure! If the panel is wired
in parallel with the phone
line and this option is on, the
panel detects a “line cut”
whenever the phone is in
use.
The range is 02-48 in 5 second increments, with 02 being a 10 second delay and 48 being a 240
second delay.
¾
To turn on Line Cut Detection, press:
Add—Option #—70—02 - 48—DONE.
¾
To turn off Line Cut Detection, press:
Delete—Option #—70—DONE.
Option 71: Programming Report (Default = off)
Determines whether the panel sends a report to the central station anytime the programming
mode is entered/exited (on) or not at all (off).
The panel sends a report whenever the dealer (Utility 1) or installer (Utility 2) code is used to
enter programming mode and another report is sent when the programming session ends (when
the cover is closed).
¾
To turn on Programming Report, press:
Add—Option #—71—DONE.
¾
To turn off Programming Report, press:
Delete—Option #—71—DONE.
Option 72: Supervisory Time (Default = 12:00am)
Determines when the panel reports supervisory conditions (sensor failures) and automatic
phone tests to the central station.
Note
The panel clock must be set
to the correct time for this
option and Option 16: Auto
Phone Test to work correctly.
¾
To set Supervisory Time, press:
Add—Option #—72—Hours—Minutes—DONE.
¾
To turn off (disable) Supervisory Time, press:
Delete—Option #—71—DONE.
SIA Limits
Affected Option
SIA Limits (Option 69
on)
Factory Ranges (Option 69
off)
Option 10: Entry Delay
030-254 seconds
005-254 seconds
Option: 11 Exit Delay
045-254 seconds
005-254 seconds
Option: 17 Dialer Delay
015-045 seconds
005-254 seconds
Summary of Contents for Euro Simon