Chapter 1
Introduction
5
Minimum load requirements
Table 1
lists the load requirements for all CyberDome II dome configurations.
Cable requirements
Table 2
lists the requirements for the cables that connect to the dome.
Note:
When using unshielded twisted-pair cable for video and data, the wires can share the same jacket but must remain
separate twisted pairs.
CAUTION:
For safety, the mounting surface, hardware, and procedure used for securing the dome must support
the weight of the dome, mount (if used), cables, and any structural or environmental vibration according
to local codes.
Table 1.
Minimum load requirements of dome configurations
Minimum load
Dome configuration
100 lb.
• Rugged, cast aluminum pendant-mount housing (with any mount)
• Heavy-duty housing (with any mount)
• Pressurized housing gooseneck (specia)
• Swing-arm mount (with any dome except heavy duty or flush-mount)
50 lb.
All other dome and mount configurations
Table 2.
Cable requirements
Operation
Cable requirement
Length
feet
meters
Data
For RS-422:
22 gauge (0.64 mm)
unshielded
, two-conductor, twisted-pair (UTP) cable 10,000
3,000
For RS-485:
22 gauge (0.64 mm)
shielded
, two-conductor, twisted-pair (STP) cable
3,000
900
Power
24 VAC cable. To determine the size of cable needed for individual applications, see
Power cable size and length requirements
on page 7.
Video
75 ohm coaxial cable; or
22 gauge (0.64 mm) unshielded, two-conductor, twisted-pair (UTP) cable
Note:
Use only crimp-on BNC connectors. Do not use screw-on connectors.
Summary of Contents for CyberDome II
Page 1: ...CyberDome II Installation Manual ...
Page 8: ...CyberDome II Installation Manual viii ...
Page 16: ...CyberDome II Installation Manual 8 ...
Page 26: ...CyberDome II Installation Manual 18 ...
Page 40: ...CyberDome II Installation Manual 32 ...