12. SCHEMATICS SINGLE BUSBAR
12-14
BUS1000 Busbar Protection
GEK-98514B
FUNCTIONAL UNIT
DEVICE TYPE
DESCRIPTION
3B / 87
LATCHING RELAY
Lockout relay 3B/87
3BX / 87
TEST UNIT
Auxiliary of 3B/87
3P / 87
AUXILIARY RELAY HLA Testing auxiliary relay
3PX / 87
TEST UNIT
Auxiliary of 3P/87
3PY / 87
TEST UNIT
Testing auxiliary relay
43/AL – DIFF.
TEST UNIT DPR
Selector switch of alarm diff. Test
43/TAPS
TEST UNIT DPR
Selector switch of tap selection
43/
∅
1, 43/2, 43/3
TEST UNIT DPR
Selector switch of phase selection
50 + BF/ P1_ _ _ _ P5
MFI
B.F. & overcurrent supervision relays / positions
P1_ _ _ _ P5
50/P1_ _ _ _ P5
MFI
Overcurrent supervision contact positions P1_ _
_ _ P5
52/ P1_ _ _ _ P5
BREAKER
Breaker/ position P1_ _ _ _ P5
87 (
∅
1,
∅
2,
∅
3)
BUS1000
Differential relay, phases (
∅
A,
∅
B,
∅
C)
RE
BUS1000
Stabilising resistor
T. DIF
BUS1000
Differential circuit input current transformer
AL
BUS1000
Alarm unit
RD
BUS1000
Differential Voltage resistor
RF
BUS1000
Restraint Voltage Resistor
TRIP
BUS1000
Differential trip unit
UM
BUS1000
Measuring unit
87X/ TRIP
DRD102
Auxiliaries of 87 / TRIP
BF/ P1_ _ _ _ P5
EXTERNAL CONTACT
Breaker failure initiation positions P1_ _ _ P5
P1 _ _ _ _ P5/TF
DFI1
Restraint transf. positions P1 _ _ _ _ P5 (input
module)
P1 _ _ _ _ P5/TM
DFI1
Measuring transformer positions P1_ _ _ _ P5
B.F./A
DTE
Breaker failure
B.F./P1_ _ _ _ P5
SFI
Breaker failure positions P1_ _ _ _ P5
B.F./AX
DTE
Auxiliary of BF/AB
PB/L
TEST RACK
Blocking lamp
PB/87
TEST RACK
Blocking pushbutton
PP/L
TEST RACK
Test lamp
PP/87
TEST RACK
Test pushbutton
PR/L
TEST RACK
Reset lamp
PR/87
TEST RACK
Rest pushbutton
TP1_ _ _ _ TP5
Terminal
Differential and restraint voltage measuring
points
TI AUX/P1_ _ _ _ P5
TRANSFORMER
226B2999
Auxiliary current transformer / positions P1_ _ _
_ P5
TI/P1_ _ _ _ P5
MAIN C.T.
Main current transformer / positions P1_ _ _ _
P5
PPY/87
AUXILIARY RELAY
Auxiliary remote reset
3R/87
AUXILIARY RELAY
189C6051G1
Stabilisation resistor shorting relay
226B2898G2
Breaker failure power supply auxiliary resistors
box
226B2898G3
Differential power supply auxiliary resistors box
PK-2
PK-2
Block test 6 poles
NOTE: Terminals starting by A are part of the Differential rack
Terminals starting by B are part of the Test rack
Terminals starting by C are part of the Breaker failure rack
Terminals starting by D are part of the DTE rack
Terminals starting by F are part of the Differential power supply
Terminals starting by K are part of the Test block
Terminals starting by P are part of the breaker failure power supply
Terminals starting by T are part of the Thyrite box
FIGURE B2211F59. LEGEND
Summary of Contents for BUS1000
Page 6: ......
Page 8: ......
Page 34: ...5 HARDWARE DESCRIPTION 5 10 BUS1000 Busbar Protection GEK 98514B ...
Page 36: ...6 RECEIVING HANDLING AND STORAGE 6 2 BUS1000 Busbar Protection GEK 98514B ...
Page 54: ...8 FINAL INSTALLATION AND COMMISSIONING 8 4 BUS1000 Busbar Protection GEK 98514B ...
Page 56: ...9 TESTS AND PERIODICAL MAINTENANCE 9 2 BUS1000 Busbar Protection GEK 98514B ...
Page 66: ...10 FIGURES 10 10 BUS1000 Busbar Protection GEK 98514B ...
Page 74: ...11 DIMENSIONS 11 8 BUS1000 Busbar Protection GEK 98514B FIGURE 23 CABINET 226B2211F21 ...
Page 104: ...13 SCHEMATICS DOUBLE BUSBAR 13 16 BUS1000 Busbar Protection GEK 98514B ...