Section 21 - Appendix A – Monitor Options for PWA 140720-01
45
21.2 Main Board Option Settings
All monitor option jumpers for the Dual Vibration Monitor are on the Main Board. The
following table lists these options and their jumper positions.
Option Settings on Newer Version of the Main Board (Part Number 140720-01)
JUMPER
OPTION
SETTING
INSTALL REMOVE
First Out
Enabled *
Disabled
----------
W20I
W20I
----------
Alert Mode
Latching *
Nonlatching
----------
W20G
W20G
----------
Danger Mode
Latching *
Nonlatching
----------
W20F
W20F
----------
Danger Voting
And Relay Drive
Or Relay Drive *
W20H
----------
----------
W20H
Danger Bypass Switch
Enabled
Disabled *
W20C
----------
----------
W20C
Vibration Alarm Delay **
0.1 s.
1 s.
3 s. *
6 s.
W20A
W20A,B
----------
W20B
W20B
----------
W20A,B
W20A
Gap Alarm
Enabled
Disabled *
W20D
----------
----------
W20D
Recorder Clamping Mode
+4 to 20 mA Rec. only
NOT OK = 4 mA
NOT OK = 2 mA*
----------
W17E, F
W17E, F
----------
Corner Frequency Option
60-36,000 RPM
240-240,000 RPM*
W15B, C,
W16E-H, M-P
W15A, D,
W16A-D, I-L
W15A, D,
W16A-D, I-L
W15B, C,
W16E-H, M-P
* Standard configuration as shipped from factory.