Section 12 - Alarm Setpoint Adjustment
23
12.2 Gap Alert Setpoint Adjustment
1. To adjust Gap Alert
setpoints, first select Under
Gap setpoints by setting
the Over/Under (
O/U
)
switch to the right.
2. Press and hold the
GAP
and
ALERT
switches
simultaneously on the front
panel. The left bargraph
will flash the Gap Alert
setpoint window. Use the
center meter scale.
3. Use the (
↑
) or (
↓
) switches
on the System Monitor to
adjust the Under Gap
setpoint level up or down.
4. Repeat steps 2 and 3 for
Over Gap Alert setpoints
after setting the Over/Under
(
O/U
) switch to the left.
5. Reset
AA
to the right
(OFF).
12.3 Channel B
Adjust
1. Set the Adjust channel B
switch (
AB
) to the left (ON)
and repeat steps
12.1.3,
12.1.4
and section
12.2
above.
2. Reset
AB
to the right
(OFF).
3. Close
front
panel.