Installation Instructions
MINIMUM CLEARANCES
(Appearance may vary)
Mounting the outdoor unit:
The distance between
the indoor unit and the
�o
or should be more
than 6 feet.
more than
4in.
more than
4in.
more than
4in.
more than
4in.
more than
6in.
more than
24in.
more than
6in.
Attention must be paid to
the pitch of drain hose
Z
1
2
Refer to the table below for mounting feet
positions and submittal for unit dimensions.
Mounting feet positions for the outdoor unit.
Securely attach the unit to a mounting pad
or brackets with 7/16" (10mm) bolts.
Use the mounting feet pads or vibration mats
where noise transmission may be a concern.
Follow local code when mounting the unit
on a wall, rooftop, or an area a�ected by
strong winds or earthquakes.
This picture is for reference only. Your product may look different. Read your manual before installation.
Explain the operation of the unit to the user according to this manual.
Piping Exit Options
Rear left
Left
Rear
right
Right
Below
Marketing Model Number
X1(inch)
X2(inch)
Y(inch)
Z(inch)
ASH124CRDWA
5.12
5.12
25.98
15.75
ASH124PRDWA
ASH118URDSD
ASH109CRAWA
5.47
5.51
19.69
10.20
ASH112CRAWA
ASH118CRDWA
5.16
5.16
24.72
14.53
ASH115PRDWA
ASH118PRDWA
ASH109URDSD
ASH112URDSD
ASH109PRDWA
5.12
5.91
19.69
12.20
ASH112PRDWA