September 2004
1-6
Installation
Making Electrical
Connections
This section contains instructions for making all the necessary
electrical connections to the AT868 electronics console. Refer to
Figure 1-5
on page 1-16 for a complete wiring diagram.
!ATTENTION EUROPEAN CUSTOMERS!
To meet CE Mark requirements, all cables must be installed
as described in the previous section
!WARNING!
Always disconnect the line power from the AT868 before
removing the front cover.
Preliminary Steps
Before making any electrical connections, prepare the AT868 by
completing the following steps:
1.
Disconnect any previously wired power line from the unit.
2.
Remove the screws on the front cover.
3.
Loosen the two screws and remove the plastic shroud that protects
the electrical connections.
Note:
For compliance with the European Union’s Low Voltage
Directive (73/23/EEC), a transparent plastic shroud protects
the electrical connections. The shroud must remain in place,
except while wiring the unit. Reinstall the shroud after the
wiring has been completed.
4.
Install any required cable clamps in the appropriate conduit holes
on the bottom of the enclosure.
5.
Note the labels inside the enclosure to assist in wiring.
Proceed to the appropriate section of this chapter to make the required
wiring connections.