background image

Installation Instructions

 

 PREPARE THE AIR CONDITIONER

Install the top moutning rail with Type A screws, 

4 for AHH12 and AHH10 and 3 for AHH08 from 

the outside of the case. 

Slide the side curtain panels into the side 
panel rails.

Slide left and right side curtain frames 
into top and bottom rails.  Make sure that 
side curtains snap into side of the frames.

3

A

B

9

  WINDOW REQUIREMENTS

‡

These instructions are for a standard double-hung 

window. You will need to modify them for other types 

of windows.

‡

The air conditioner can be installed without the 

side curtain panels if needed to fit in a narrow 

window. See the window opening dimensions.

‡

All supporting parts must be secured 

to firm wood, masonry or metal.

‡

The electrical outlet must be within reach of the 

power cord.

‡

Follow the dimensions in the table and illustration 

for your model.

      Models 

B

AHH08LP 13 

3/8

s

min. 25

s

– 36

s

 

AHH10AP, 14 

9/16

s

min. 24 

1/2

s

– 38

s

AHH12AP

  STORM WINDOW REQUIREMENTS

A storm window frame will not allow the air 

conditioner to tilt toward the outside, and will keep it 

from draining properly.  

To adjust for this, attach a piece of wood to the sill.

WOOD PIECES
WIDTH: 2

s

LENGTH: 

Long enough to fit inside the window 

frame.

THICKNESS: 

To determine the thickness, place a 

piece of wood on the sill to make it 1/2

s

 higher 

than the top of the storm window frame or the vinyl 

frame.
Attach securely with nails or screws provided by the 

installer.

1

A

(With side curtain panels)

B

2

1/2

s

higher

than storm 

window 

frame

Storm window 

frame

Wood

Sill

1/2

s

higher

than vinyl frame  

(on some windows)

Vinyl frame

C

Top left

Top right

Top mounting rail

Bottom mounting rail

Top Mounting rail

Bottom mounting rail

Summary of Contents for AHH10

Page 1: ...a 16 Warranty for Customers in the U S A 15 49 7676 12 10 GE AHH08 AHH10 AHH12 Owner s Manual and Installation Instructions Write the model and serial numbers here Model __________________________ Ser...

Page 2: ...trician These R410A air conditioning systems require contractors and technicians to use tools equipment and safety standards approved for use with this refrigerant DO NOT use equipment certified for R...

Page 3: ...AREFULLY SAVE THESE INSTRUCTIONS WARNING USE OF EXTENSION CORDS RISK OF FIRE Could cause serious injury or death DO NOT use an extension cord with this Window Air Conditioner DO NOT use surge protecto...

Page 4: ...ically turn off in 1 to 24 hours How to set Press the Delay 1 24hr pad on the unit or the remote control Each touch of the Increase Decrease pads on the unit or the Increase Decrease pads on the remot...

Page 5: ...FW WKH Cool mode and High or Med fan with a middle set temperature For Maximum Cooling 6HOHFW WKH Cool mode and High fan with a lower set temperature For Quieter and Nighttime Cooling 6HOHFW WKH Cool...

Page 6: ...t new battery making sure that the and of battery are installed correctly 3 Reattach the cover by twisting it back into position NOTES Use one CR 2025 3V Lithium battery Remove the batteries from the...

Page 7: ...y to have it replaced with a properly grounded 3 prong wall outlet Some models require 230 208 volt AC protected with a time delay fuse or circuit breaker These models should be installed on their own...

Page 8: ...ation Instructions Side Curtain Frame 2 Type B 9 Foam top window gasket Side Curtain 2 Top mounting rail Air conditioner Window locking bracket 1 Side Brackets 2 PARTS INCLUDED Appearance may vary Rem...

Page 9: ...be within reach of the power cord Follow the dimensions in the table and illustration for your model Models A B AHH08LP 13 3 8s min 25s 36s AHH10AP 14 9 16s min 24 1 2s 38s AHH12AP STORM WINDOW REQUI...

Page 10: ...eft side A B C D 10 INSTALL THE AIR CONDITIONER IN THE WINDOW Mark the center of the window Set the air conditioner in the window so that is it centered Place the air conditioner so that front edge of...

Page 11: ...am between the glass and the window to prevent air and insects from getting into the room NOTE If the gasket supplied does not fit your window obtain appropriate material locally to provide a proper i...

Page 12: ...r cord plug device is tripped tIf the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician Air conditioner does Airflow is restricted tM...

Page 13: ...13 Notes...

Page 14: ...14 Notes...

Page 15: ...haser and any succeeding owner for products purchased for home use within the USA Some states do not allow the exclusion or limitation of incidental or consequential damages This warranty gives you sp...

Page 16: ...1 Factory Lane Moncton N B E1C 9M3 Parts and Accessories In the U S A GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes...

Page 17: ...s Normales de Funcionamiento 11 Soporte al Cliente Garant a para Clientes en EE UU 13 Soporte al Cliente 14 Manual del Propietario e Instrucciones de Instalaci n Escriba los n meros de modelo y de ser...

Page 18: ...cos utilicen herramientas equipamiento y est ndares de seguridad aprobados para su uso con este refrigerante NO use equipamiento certificado s lo para refrigerante R22 PRECAUCIONES DE SEGURIDAD Nunca...

Page 19: ...DOSAMENTE GUARDE ESTAS INSTRUCCIONES RIESGO DE INCENDIO Podr a ocasionar lesiones graves o la muerte NO use un prolongador con este Acondicionador de Aire de Ventana NO use protectores contra picos de...

Page 20: ...or de aire se encuentre encendido se podr configurar autom ticamente para que se apague en un per odo de entre 1 y 24 horas C mo configurar Presione la tecla Delay 1 24hr Retraso entre 1 y 24 hrs en l...

Page 21: ...la temperatura deseada Ajuste el termostato a un n mero menor y el aire interno se enfriar m s Si lo ajusta a un n mero mayor la temperatura del aire interno se calentar m s NOTA si el acondicionador...

Page 22: ...evas asegur ndose de que el y de las pilas est n instalados correctamente 3 Vuelva a colocar la tapa girando la misma nuevamente hasta su posici n NOTES Use una pila de Litio CR 2025 3V Retire las pil...

Page 23: ...e acondicionador de aire Los cables caseros de aluminio podr an presentar problemas especiales Consulte a un t cnico electricista calificado ANTES DE INICIAR Lea estas instrucciones completa y cuidado...

Page 24: ...de montaje superior Acondicionador de aire Soporte de Cierre de la Ventana 1 Soportes Laterales 2 PARTES INCLUIDAS La apariencia puede variar Control Remoto Tipo A 4 HERRAMIENTAS QUE NECESITAR Un des...

Page 25: ...el ctrico del acondicionador de aire Siga las dimensiones de la tabla y la ilustraci n seg n su modelo Models A B AHH08LP 13 3 8s min 25s 36s AHH10AP 14 9 16s min 24 1 2s 38s AHH12AP 1 A con paneles...

Page 26: ...ENTANA Marque el centro de la ventana Coloque el acondicionador de aire en la ventana de modo que se encuentre centrado Coloque el acondicionador de aire de modo que el extremo frontal del riel de mon...

Page 27: ...la gomaespuma entre el vidrio y la ventana para evitar el ingreso de aire e insectos a la habitaci n NOTA Si la junta provista no se ajusta a su ventana obtenga el material apropiado en forma local p...

Page 28: ...ando el acondicionador de aire se enciende usted estado caliente necesita darle tiempo para que enfri la habitaci n El aire fr o se est escapando Cerci rese de que los registros de la calefacci n no e...

Page 29: ...13 Notas...

Page 30: ...14 Notas...

Page 31: ...e extiende al comprador original y cualquier comprador posterior de productos comprados para uso residencial dentro de Estados Unidos Algunos estados no permiten la exclusi n o las limitaciones de da...

Page 32: ...con dificultades auditivas favor de llamar al 800 TDD GEAC 800 833 4322 Piezas y accesorios GEAppliances com Aquellos individuos con la calificaci n necesaria para reparar sus propios electrodom stic...