IMPORTANT SAFETY INFORMATION.

READ ALL INSTRUCTIONS BEFORE USING.

WARNING!

For your safety, the information in this manual must be followed to minimize the risk of fire, electric 

shock or personal injury.

„

Use this appliance only for its intended 

purpose as described in this Owner’s 

Manual. 

„

This air conditioner must be properly 

installed in accordance with the Installation 

Instructions before it is used. 

„

Never unplug your air conditioner by pulling 

on the power cord. Always grip plug firmly 

and pull straight out from the receptacle. 

„

Replace immediately all electric service 

cords that have become frayed or otherwise 

damaged. A damaged power supply cord 

must be replaced with a new power supply 

cord obtained from the manufacturer and 

not repaired. Do not use a cord that shows 

cracks or abrasion damage along its length  

or at either the plug or connector end. 

„

Turn the unit

 OFF

 and unplug your air 

conditioner before cleaning. 

„

GE does not support any servicing of the 

air conditioner. We strongly recommend 

that you do not attempt to service the air 

conditioner yourself.

„

For your safety…do not store or use 

combustible materials, gasoline or other 

flammable vapors or liquids in the vicinity  

of this or any other appliance.

„

All air conditioners contain refrigerants, 

which under federal law must be removed 

prior to product disposal. If you are getting 

rid of an old product with refrigerants, check 

with the company handling disposal about 

what to do.

„

If the receptacle does not match the plug, 

the receptacle must be changed out by a 

qualified electrician.

„

These R410A air conditioning systems 

require contractors and technicians to  

use tools, equipment and safety standards 

approved for use with this refrigerant.  

DO NOT use equipment certified for  

R22 refrigerant only.

SAFETY PRECAUTIONS

Do not, under any circumstances, cut or remove 

the third (ground) prong from the power cord.  

For personal safety, this appliance must be 

properly grounded.

  DO NOT use an adapter plug with this appliance.

The power cord of this appliance is equipped 

with a 3-prong (grounding) plug which mates 

with a standard 3-prong (grounding) wall outlet 

to minimize the possibility of electric  

shock hazard from this appliance.
Power cord includes a current interrupter device. 

A test and reset button is provided on the plug 

case. The device should be tested on a periodic 

basis by first pressing the 

TEST

 button and 

then the 

RESET 

button while plugged into the 

outlet. If the

 TEST

 button does not trip or if the 

RESET 

button will not stay engaged, discontinue 

use of the air conditioner and contact a qualified 

service technician.

Have the wall outlet and circuit checked by  

a qualified electrician to make sure the outlet  

is properly grounded.
Where a 2-prong wall outlet is encountered,  

it is your personal responsibility and obligation to 

have it replaced with a properly grounded  

3-prong wall outlet.
The air conditioner should always be plugged 

into its own individual electrical outlet which has 

a voltage rating that matches the rating plate.
This provides the best performance and also 

prevents overloading house wiring circuits which 

could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical 

Requirements section for specific electrical 

connection requirements. 

HOW TO CONNECT ELECTRICITY

Summary of Contents for AHH10

Page 1: ...a 16 Warranty for Customers in the U S A 15 49 7676 12 10 GE AHH08 AHH10 AHH12 Owner s Manual and Installation Instructions Write the model and serial numbers here Model __________________________ Ser...

Page 2: ...trician These R410A air conditioning systems require contractors and technicians to use tools equipment and safety standards approved for use with this refrigerant DO NOT use equipment certified for R...

Page 3: ...AREFULLY SAVE THESE INSTRUCTIONS WARNING USE OF EXTENSION CORDS RISK OF FIRE Could cause serious injury or death DO NOT use an extension cord with this Window Air Conditioner DO NOT use surge protecto...

Page 4: ...ically turn off in 1 to 24 hours How to set Press the Delay 1 24hr pad on the unit or the remote control Each touch of the Increase Decrease pads on the unit or the Increase Decrease pads on the remot...

Page 5: ...FW WKH Cool mode and High or Med fan with a middle set temperature For Maximum Cooling 6HOHFW WKH Cool mode and High fan with a lower set temperature For Quieter and Nighttime Cooling 6HOHFW WKH Cool...

Page 6: ...t new battery making sure that the and of battery are installed correctly 3 Reattach the cover by twisting it back into position NOTES Use one CR 2025 3V Lithium battery Remove the batteries from the...

Page 7: ...y to have it replaced with a properly grounded 3 prong wall outlet Some models require 230 208 volt AC protected with a time delay fuse or circuit breaker These models should be installed on their own...

Page 8: ...ation Instructions Side Curtain Frame 2 Type B 9 Foam top window gasket Side Curtain 2 Top mounting rail Air conditioner Window locking bracket 1 Side Brackets 2 PARTS INCLUDED Appearance may vary Rem...

Page 9: ...be within reach of the power cord Follow the dimensions in the table and illustration for your model Models A B AHH08LP 13 3 8s min 25s 36s AHH10AP 14 9 16s min 24 1 2s 38s AHH12AP STORM WINDOW REQUI...

Page 10: ...eft side A B C D 10 INSTALL THE AIR CONDITIONER IN THE WINDOW Mark the center of the window Set the air conditioner in the window so that is it centered Place the air conditioner so that front edge of...

Page 11: ...am between the glass and the window to prevent air and insects from getting into the room NOTE If the gasket supplied does not fit your window obtain appropriate material locally to provide a proper i...

Page 12: ...r cord plug device is tripped tIf the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician Air conditioner does Airflow is restricted tM...

Page 13: ...13 Notes...

Page 14: ...14 Notes...

Page 15: ...haser and any succeeding owner for products purchased for home use within the USA Some states do not allow the exclusion or limitation of incidental or consequential damages This warranty gives you sp...

Page 16: ...1 Factory Lane Moncton N B E1C 9M3 Parts and Accessories In the U S A GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes...

Page 17: ...s Normales de Funcionamiento 11 Soporte al Cliente Garant a para Clientes en EE UU 13 Soporte al Cliente 14 Manual del Propietario e Instrucciones de Instalaci n Escriba los n meros de modelo y de ser...

Page 18: ...cos utilicen herramientas equipamiento y est ndares de seguridad aprobados para su uso con este refrigerante NO use equipamiento certificado s lo para refrigerante R22 PRECAUCIONES DE SEGURIDAD Nunca...

Page 19: ...DOSAMENTE GUARDE ESTAS INSTRUCCIONES RIESGO DE INCENDIO Podr a ocasionar lesiones graves o la muerte NO use un prolongador con este Acondicionador de Aire de Ventana NO use protectores contra picos de...

Page 20: ...or de aire se encuentre encendido se podr configurar autom ticamente para que se apague en un per odo de entre 1 y 24 horas C mo configurar Presione la tecla Delay 1 24hr Retraso entre 1 y 24 hrs en l...

Page 21: ...la temperatura deseada Ajuste el termostato a un n mero menor y el aire interno se enfriar m s Si lo ajusta a un n mero mayor la temperatura del aire interno se calentar m s NOTA si el acondicionador...

Page 22: ...evas asegur ndose de que el y de las pilas est n instalados correctamente 3 Vuelva a colocar la tapa girando la misma nuevamente hasta su posici n NOTES Use una pila de Litio CR 2025 3V Retire las pil...

Page 23: ...e acondicionador de aire Los cables caseros de aluminio podr an presentar problemas especiales Consulte a un t cnico electricista calificado ANTES DE INICIAR Lea estas instrucciones completa y cuidado...

Page 24: ...de montaje superior Acondicionador de aire Soporte de Cierre de la Ventana 1 Soportes Laterales 2 PARTES INCLUIDAS La apariencia puede variar Control Remoto Tipo A 4 HERRAMIENTAS QUE NECESITAR Un des...

Page 25: ...el ctrico del acondicionador de aire Siga las dimensiones de la tabla y la ilustraci n seg n su modelo Models A B AHH08LP 13 3 8s min 25s 36s AHH10AP 14 9 16s min 24 1 2s 38s AHH12AP 1 A con paneles...

Page 26: ...ENTANA Marque el centro de la ventana Coloque el acondicionador de aire en la ventana de modo que se encuentre centrado Coloque el acondicionador de aire de modo que el extremo frontal del riel de mon...

Page 27: ...la gomaespuma entre el vidrio y la ventana para evitar el ingreso de aire e insectos a la habitaci n NOTA Si la junta provista no se ajusta a su ventana obtenga el material apropiado en forma local p...

Page 28: ...ando el acondicionador de aire se enciende usted estado caliente necesita darle tiempo para que enfri la habitaci n El aire fr o se est escapando Cerci rese de que los registros de la calefacci n no e...

Page 29: ...13 Notas...

Page 30: ...14 Notas...

Page 31: ...e extiende al comprador original y cualquier comprador posterior de productos comprados para uso residencial dentro de Estados Unidos Algunos estados no permiten la exclusi n o las limitaciones de da...

Page 32: ...con dificultades auditivas favor de llamar al 800 TDD GEAC 800 833 4322 Piezas y accesorios GEAppliances com Aquellos individuos con la calificaci n necesaria para reparar sus propios electrodom stic...

Reviews: