23. Unlock, lock, disable and enable doors
Use this function to unlock, lock disable and enable a valid door via the LCD arming station.
The function can only be used with door numbers 17 to 64. I.e. doors controlled by four-door DGPs.
The door remains in the state selected until an opposite event occurs in the system that will change the state of
that door, for example, Door 21 automatically unlocks at 08:00H and relocks at 17:00H (using an "Override
Timezone").
If the user wants to arm the premises and leave at 16:00, the door can be locked using the "lock" option, but
will still automatically unlock at 08:00 again the following morning.
To unlock, lock, disable or enable a door via the arming station
1. Access menu option 23.
The display shows:
1-Unlock 2-Lock 3-Disable 4-Enable
Option:
2. Enter the door function option you want to do and press
[ENTER]
, or
press
[ENTER]
to return to the menu.
The display shows the option selected:
Example:
Unlock Door
Door No:
3. Enter the door number to unlock and press
[ENTER]
to return to the menu, or
press only
[ENTER]
to return to the menu.
Only doors programmed to be opened by your code can be operated using this option. For example, the door group
assigned to the user may not allow access to all doors.
See Also:
Door and Floor Groups - Menu Option 20 on page