19
Active zones (when arming)
You cannot arm (or disarm, if your system is programmed that way) an area unless all the zones in that area
are normal, as an active zone would usually set off an alarm. For example, all the doors and windows must be
closed.
If a zone is active while you try to arm or disarm an area, the Advisor MASTER keypad sounds seven quick
beeps and displays the active zones.
Active zones are listed either:
One at a time
Example:
Active On 6. Front Door
NEXT or ENTER
or
As a list of numbers
Example:
Active On 6, 7, 9.
Zone No:
From either display:
Action Result
Press
[NEXT]
Update the list of active zones and display the next zones in the list (if any).
Enter area number and press
[ENTER]
Display the zone name in full.
Press
[CLEAR]
Exit the function and return to the display shown when you were
attempting to arm the system.
After you have determined which zones are active, you must check these and correct the problem (for
example, close the door), then exit this display, and try again to arm. If you are unable to close the zone, refer
to
Menu option 10, Inhibit Zone
.
See also:
; Disarming Your System on page