P
ITOT
S
TATIC
K0553 Revision D
44
[EN] English
Figure 3-10: Nudge Increment/Decrement factor selection
- Select the new factor (7) from the list. The new factor is selected and the increment/decre-
ment factor panel closes.
- Touching the up/down controls (5/6) will increment/decrement the “Rate Aim” value by
the new factor.
5)
Touch the “Tick” icon (3), the new value appears in the “Aim” field. The altitude value
changes to the new value, at the rate of change value, and provided that the new value is
within acceptable limits the text will turn green.
6)
Touching the “Cross” icon (4), cancels the action and closes the keypad.
NOTE
:
It is possible to change multiple values at the same time by selecting the appropriate aim
values (Repeat items 1 to 4 above) and then touch the “Tick” item once all changes have been
entered. This method is preferable on the ADTS553/554 products as on a multichannel controller
system it is preferable for all controllers to start at the same time.
- CAS (CAS1, CAS2 on ADTS554)
Displays the currently selected calibrated air speed. To change the value, repeat the same
procedure as above for ALT.
- Mach (MACH1, MACH2 on ADTS554)
Displays the current selection. To change the value, repeat the same procedure as above for ALT.
Ps, Pt and Qc
The following controls are available when “Pressure” units are selected:
Summary of Contents for ADTS542F
Page 19: ...Chapter 1 Introduction ...
Page 30: ...DUAL HAND TERMINAL EN English 19 K0553 Revision D Figure 1 8 ADTS Touch Slave ...
Page 31: ...Chapter 2 Installation ...
Page 34: ...PACKING FOR STORAGE OR TRANSPORTATION EN English 24 K0553 Revision D ...
Page 40: ...Chapter 3 Operation ...
Page 114: ...Chapter 4 Calibration ...
Page 123: ...Chapter 5 Maintenance ...
Page 132: ...Chapter 6 Testing and Fault Finding ...
Page 152: ...Chapter 7 Specification ...