THREE-CONDUCTOR BRANCH
CIRCUIT CONNECTION
When connecting to a 3-conductor branch
circuit, if local codes permit:
Connect the bare oven ground conductor
with the crimped neutral (white) lead to
the branch circuit neutral (white or gray
in color), using wire nuts.
Connect the oven red lead to the branch
circuit red lead, and the oven black lead to
the branch circuit black lead in accordance
with local codes, using wire nuts. If the
residence red, black or white leads are
aluminum conductors, see “WARNING”
note (see page 6).
7b
7a
Cut the neutral (white) lead from the
crimp. Re-strip the neutral (white) lead to
expose the proper length of conductor
and connect it to the white or gray branch
circuit neutral in accordance with local
code using wire nuts.
Attach the appliance grounding lead
(green or bare copper) in accordance with
local codes. If the residence grounding
conductor is aluminum, see WARNING
note (see page 6).
Connect the oven red lead to the branch
circuit red lead and the oven black lead to
the branch circuit black lead in accordance
with local codes, using wire nuts. If the
residence red, black or white leads are
aluminum conductors, see “WARNING”
note (see page 6).
7c
7b
7a
NEW CONSTRUCTION AND
FOUR-CONDUCTOR BRANCH
CIRCUIT CONNECTION
•
When installing in new construction, or
•
When installing oven in a mobile home or
recreational vehicle, or
•
When local codes do not permit grounding
through neutral:
Branch
circuit
Black
Alternate
knockout
Neutral bare wire
connection
Range conduit
snaps into box
Red
Ground and
neutral wires
(white)
Branch
circuit
Black
Alternate
knockout
Range conduit
snaps into box
Red
White
Ground
wires
7
Installation Instructions