Do not shorten the flexible conduit. The conduit strain relief clamp must be securely attached to
the junction box and the flexible conduit must be securely attached to the clamp. If the flexible
conduit will not fit within the junction box, do not install the oven until a clamp of the proper
size is obtained.
NOTE TO ELECTRICIAN:
The 3 power leads supplied with this appliance are UL recognized
for connection to larger gauge household wiring. The insulation of these 3 leads is rated at
temperatures much higher than the temperature rating of household wiring. The current carrying
capacity of the conductor is governed by the temperature rating of the insulation around the wire,
rather than the wire gauge alone.
ELECTRICAL CONNECTIONS
(CONT.)
Reinstall Junction box cover.
8
8
Installation Instructions