NX-1750
PROGRAMMING WORKSHEETS
(Factory defaults are in
bold italic
text)
LOC
PG
DESCRIPTION
DEFAULT
YOUR DATA
0
13 SCAN
FUNCTIONS
Seg 1 SINGLE BEEP FUNCTION
8
1 =
"On" to send Code Entry function to the control panel.
2 =
"On" to activate the Armed Away mode.
3 =
"On" to activate the Armed Stay mode.
4 =
"On" to send the Disarm function to the control panel.
5 =
"On" to send Auxiliary Function #1 to the control panel.
6 =
"On" to send Auxiliary Function #2 to the control panel.
7 =
"On" to broadcast an X-10 function (Loc 241 for programming).
8 =
"On" to send an RTE; and activate the onboard relay output.
Seg 2 DOUBLE BEEP FUNCTION
8
1 =
"On" to send Code Entry function to the control panel.
2 =
"On" to activate the Armed Away mode.
3 =
"On" to activate the Armed Stay mode.
4 =
"On" to send the Disarm function to the control panel.
5 =
"On" to send Auxiliary Function #1 to the control panel.
6 =
"On" to send Auxiliary Function #2 to the control panel.
7 =
"On" to broadcast an X-10 function (Loc 241 for programming).
8 =
”On" to send an RTE; and activate the onboard relay output.
Seg 3 TRIPLE BEEP FUNCTION
8
1 =
"On" to send Code Entry function to the control panel.
2 =
"On" to activate the Armed Away mode.
3 =
"On" to activate the Armed Stay mode.
4 =
"On" to send the Disarm function to the control panel.
5 =
"On" to send Auxiliary Function #1 to the control panel.
6 =
"On" to send Auxiliary Function #2 to the control panel.
7 =
"On" to broadcast an X-10 function (Loc 241 for programming).
8 =
"On" to send an RTE; and activate the onboard relay output.
1
13 X-10
ADDRESS
Seg 1 MODULE NUMBER
0
Seg 2 HOUSE CODE
0
(see
chart)
Seg 3 SINGLE BEEP FUNCTION
2
0 =
All units off
1 =
All lights on
2 =
On
3 =
Off
4 =
Dim
5 =
Bright
6 =
All lights off
X-10 ADDRESS CODES
0=A
4=E
8=I
12=M
1=B
5=F
9=J
13=N
2=C
6=G
10=K
14=O
3=D
7=H
11=L
15=P
NX-1750 Installation manual
Page 19
18/02/05