PROGRAMMING LOCATIONS
Location 0
Programming the Scan Functions
(3 segments of binary data) Location 0 is used to select the particular function(s) that are activated when a card is
scanned. More than one function may be selected. If more than one function is selected, they will execute in order
from function 1 to function 8.
Functions 1-6 will be performed based on the user’s authority as programmed by the [
À
] [
6
]
function (refer to keypad user manual).
Segment 1
Single Beep Function
Program the functions that are performed when a card is scanned once. The buzzer will sound once.
LED1 -
"On" to send Code Entry function to the control panel.
LED2 -
"On" to activate the Armed Away mode.
LED3 -
"On" to activate the Armed Stay mode.
LED4 -
"On" to send the Disarm function to the control panel.
LED5 -
"On" to send Auxiliary/Keyfob Function #1 to the control panel.
LED6 -
"On" to send Auxiliary/Keyfob Function #2 to the control panel.
LED7 -
"On" to broadcast an X-10 function (see Location 1 for programming).
LED8 -
"On" to send a Request To Exit (RTE); and activate the onboard relay output. (Default is
“On”)
Location 3, Segment 2 must be programmed with a valid zone number for the RTE
to be sent.
Segment 2
Double Beep Function
Program the functions that are performed when a card is scanned and held at the reader for the duration of the
Scan time. The buzzer will sound twice. Location 4, Segment 1 programs the length of time between beeps. The
descriptions of the options are the same as for Single Beep Function. Default is
8.
Segment 3
Triple Beep Function
Program the functions that are performed when a card is scanned and held at the reader for the duration of 2
times the Scan time. The buzzer will sound three times. Location 4, Segment 1 programs the length of time
between beeps. The descriptions of the options are the same as for Single Beep Function. Default is
8.
Location 1
Programming the X-10 Address for the Scan Functions
(5 segments of numerical data)
Segment 1
Program a number from 0 -15 to represent the corresponding X-10
Module Number
from the following table.
Default is
0
.
Module
1
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Seg 1
0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
NX-1750 Installation manual
Page 13