LED DESCRIPTIONS
g
NetworX
Front view
ICON / LED
DESCRIPTION
ON System
armed
OFF
System not armed
(red)
Flashing
System in alarm
ON
System Ready to arm
OFF
System Not Ready to arm
(green)
Flashing
System Ready to Force arm
ON Fire
alarm
OFF Normal
(red)
Flashing Fire
trouble
ON
Mains and battery ok
OFF Mains
trouble
(green)
Flashing Battery
trouble
ON Zone
bypassed
OFF Normal
Flashing slow
Zone in alarm / Zone open
Zone 1 .. 8
(green)
Flashing fast
Zone tamper
1
1
In case of Fire, the “Fire” Icon will be ON and the NX-1750 buzzer will sound.
Badging any valid card will silence the buzzer. To clear the “Fire“ Icon
indication, badge and hold the card in front of the reader. After the fourth
beep, the “Fire” Iconwill be cleared.
Note
When the communication with the control panel fails, the “Fire” Icon will be
flashing. Typically this is caused by a fault in the databus wiring, e.g. loose
databus wire.
Note
When service is required (e.g. a system trouble condition exists), all four Icon’s
will flash once every 2.5 seconds.
Note
NX-1750 Installation manual
Page 7
18/02/05