NX-8V2 Control
33
LOC
PG
DESCRIPTION
DEFAULT
PROGRAM DATA
17
14 PHONE 3, SELECTING WHICH PARTITIONS REPORT TO PHONE 3
Segment
1
(Circle Numbers To Program)
1 = Partition 1
2 = Partition 2
3 = Partition 3
4 = Partition 4
5 = Partition 5
6 = Partition 6
7 = Partition 7
8 = Partition 8
18 15
FORMAT
OVERRIDE
Segment 1 (Circle Numbers To Program)
Segment 2 (Circle Numbers To Program)
1 =
ON - 1800hz transmit; OFF - 1900hz
2 =
ON - 2300hz handshake; OFF - 1400hz.
3 =
ON - cksum parity; OFF - double round parity
4 =
ON - 2 digit event code; OFF - 1 digit code
5 =
Reserved.
6 =
Reserved.
7 =
ON - 20 p.p.s.; OFF - 10 or 40 p.p.s.
8 =
ON - 10 p.p.s.; OFF - 20 or 40 p.p.s.
1 =
ON - pager format (no handshake required)
2 =
ON - 1400/2300 handshake
3 =
Reserved
4 =
Reserved
5 =
ON - Contact ID
6 =
ON - SIA
7 =
ON - Contact ID or 4+3
8 =
ON - DTMF
Segments 3 & 4 RESERVED
L
19
15 DOWNLOAD ACCESS CODE
8-4-8-0-0-0-0-0
_ _ _ _ _ _ _ _
L
20
15 RINGS TO ANSWER DOWNLOAD
8
_
L
21 15 DOWNLOAD
CONTROL
Segment
1
(Circle Numbers To Program)
1 =
Enables two call answering machine defeat
2 =
Enables tone sniff answering machine defeat
3 =
Requires callback before downloading
4 =
Shutdown control panel
5 =
Lock out local programming
6 =
Lock out communicator programming
7 =
Lock out download section
8 =
Enables callback at autotest interval
L
22
15 CALLBACK PHONE NUMBER
14-14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-14
__ __ __ __ __ __ __ __ __ __
__ __ __ __ __ __ __ __ __ __
L
23
15 PARTITION 1, FEATURE SELECTION
Segment
1
(Circle Numbers To Program)
1 =
Quick Arm
2 =
Re-Exit
3 =
Auto Bypass
4 =
Silent Panic
5 =
Audible Panic
6 =
Auxiliary 1
7 =
Auxiliary 2
8 =
Multi Keypress Tamper
Segment
2
(Circle Numbers To Program)
1 =
LED extinguish enable
2 =
Require user code for bypassing zones
3 =
Bypass sounder alert
4 =
AC power/low battery sounder alert
5 =
Enables bypass toggle
6 =
Enables silent auto arm
7 =
Enables automatic instant
8 =
Enables Instant mode toggle
Segment 3
(Circle Numbers To Program)
1 =
Open/Close
2 =
Bypass
3 =
Restore
4 =
Trouble
5 =
Tamper
6 =
Cancel
7 =
Recent Closing
8 = Exit Error
Segment
4
(Circle Numbers To Program)
1 =
Late to Close / Early to Open
2 =
Auto Arm in Stay Mode
3 =
Disables door delays in Night mode
4 =
Bypass Disabled for Force Arm zones
Segment 5 RESERVED
L
24
16 ENTRY / EXIT TIMERS
Segment
1
(Entry Time 1)
30
Segment 2 (Exit Time 1)
60
Segment
3
(Entry Time 2)
30
Segment
4
(Exit Time 2)
60
Segments 5 & 6
Reserved
L
25
17 ZONES 1-8, ZONE TYPES
3-5-6-6-6-6-6-6
_ _ _ _ _ _ _ _