NX-8V2 Control 

XVIII. APPENDIX 

EXPANDER NUMBERS FOR REPORTING EXPANDER TROUBLE 

 
The tables below list the device numbers that will be reported for trouble conditions. 
 

Device 

Device # reported 

 

NX-8V2 Control Panel 

See page 50 for possible report codes. 

NX-534E Two Way Listen-In 

64 

 

NX-540E “Operator” 

40 

 

NX-591E Cellemetry Interface 

76 

 

 
 

KEYPADS 

KEYPAD 

PART 1 

PART 2 

PART 3 

PART 4 

PART 5 

PART 6 

PART 7 

PART 8 

192 193 194 195 196 197 198 199 

200 201 202 203 204 205 206 207 

208 209 210 211 212 213 214 215 

216 217 218 219 220 221 222 223 

224 225 226 227 228 229 230 231 

232 233 234 235 236 237 238 239 

240 241 242 243 244 245 246 247 

248 249 250 251 252 253 254 255 

 
 

HARDWIRE EXPANDER (NX-216E) 

Starting zone number 

Expander # reported 

Zone 09  (All switches off) 

22 

Zone 09  (Switch 1 on) 

23 

Zone 17  (Switch 2 on) 

16 

Zone 25  (Switches 1 & 2 on) 

17 

Zone 33  (Switch 3 on) 

18 

Zone 41  (Switches 1 & 3 on) 

19 

 
 

REMOTE POWER SUPPLY (NX-320E) 

 

 

WIRELESS RECEIVER (NX-448E)   

 

 

Switch Setting 

Address 

Switch Setting 

Expander # reported 

All switches off 

84 

  All switches off 

35 

Switch 1 on 

85 

  Switch 1 on 

36 

Switch 2 on 

86 

  Switch 2 on 

37 

Switch 1 & 2 on 

87 

  Switches 1 & 2 on 

38 

Switch 3 on

 

88 

  Switch 3 on 

39 

Switch 1 & 3 on

 

89 

  Switches 1 & 3 on 

32 

Switch 2 & 3 on

 

90 

  Switches 2 & 3 on 

33 

Switches 1, 2, & 3 on 

91 

  Switch 1, 2 & 3 on 

34 

 
 

OUTPUT MODULE (NX-508E) 

Switch Setting 

Address 

Switch Setting 

Address 

Switch Setting 

Address 

Switch 1 & 2 on 

24 

Switch 2 & 3 on 

27 

Switch 1 on 

30 

Switch 3 on 

25 

Switch 1,2,&3 on 

28 

Switch 2 on 

31 

Switch 1 & 3 on 

26 

All switches off 

29 

 

 

 

Summary of Contents for NetworX Series

Page 1: ...NetworX Series NX 8V2 Control Panel Installation and Startup ...

Page 2: ...rd party without the written approval of GE Security Please refer to the current GE Security product catalog for detailed warranty information Main 800 727 2339 Technical Support 888 437 3287 Outside the US 903 845 6941 Sales Literature 800 547 2556 Main Fax 903 845 6811 Web www gesecurity com SAFETY SYMBOLS Warning Indicates a procedure practice condition or statement that if not strictly observe...

Page 3: ... 9 VIII PROGRAMMING DATA TYPES 9 NUMERICAL DATA 9 FEATURE SELECTION DATA 9 PROGRAMMING EXAMPLE 10 IX LOADING FACTORY DEFAULTS 11 X ENROLLING MODULES AND KEYPADS 11 XI L QUICK START INSTALLATION 11 XII PROGRAMMING LOCATIONS 11 REPORTING EVENTS TO PHONE NUMBER 1 12 REPORTING EVENTS TO PHONE NUMBER 2 13 REPORTING EVENTS TO PHONE NUMBER 3 14 XIII DEFAULT ZONE TYPES CONFIGURATIONS 16 XIV PROGRAMMING WO...

Page 4: ...tors NX 1248E 48 Zone LCD Keypad NX 216E 16 Zone Expander Module NX 1308E 8 Zone LED Door Design Keypad NX 320E Smart Power Supply and Buss Extender NX 1316E 16 Zone LED Door Design Keypad NX 408E 8 Zone Wireless Expansion Module UL listed part 60 904 NX 1324E 24 Zone LED Door Design Keypad NX 416E 16 Zone Wireless Expansion Module UL listed part 60 904 NX 1448E 48 Zone Fixed Language Icon Keypad ...

Page 5: ...NX 8V2 Control 5 IV NX 8V2 WIRING DIAGRAM ...

Page 6: ...llow the Priority zone to be used with smoke detectors COM Connect negative wire of powered devices such as motion detectors and smoke detectors AUX Connect positive wire of all powered devices except smoke detectors and keypads Individually this terminal is limited to 1 Amp Combined this terminal and KP POS are limited to 2 amps total current ZONE 8 Connect to one side of zone 8 loop Connect the ...

Page 7: ... was accepted 7 SUPPRESSES THE SERVICE LED NOTE For UL installations the Service LED shall not be suppressed Will not allow the Service LED to illuminate for any reason If there is a system trouble pressing r 2 will still show the service menu 8 ENABLE MULTI PARTITION VIEWING Enables temporary viewing of all partitions by pressing r 1 partition number r 9 4 Set Keypad Number and Partition Enter r ...

Page 8: ...essing r 9 8 while the system is disarmed will cause the control to do a callback for a download NOTE A valid user code may be required after r 9 8 if enabled in location 41 page 20 r 9 9 Pressing r 9 9 while the system is disarmed will cause the control panel to seize the phone line for a download NOTE A valid user code may be required after r 9 9 if enabled in location 41 page 20 VII PROGRAMMING...

Page 9: ...of these LEDs are as follows Zone 1 LED 1 Zone 2 LED 2 Zone 3 LED 4 Zone 4 LED 8 Zone 5 LED 16 Zone 6 LED 32 Zone 7 LED 64 Zone 8 LED 128 Example If the numerical data to be programmed in a location is 66 press 6 6 on the keypad The LEDs for Zone 2 and Zone 7 will become illuminated indicating 66 is in that location 2 64 66 See this example on page 10 Once the data is programmed press r to enter t...

Page 10: ...nging the data in the current segment FIGURE 2 Feature Selection Data Location 23 Segment 1 1 Quick Arm 2 Re Exit 3 Auto Bypass 4 Silent Keypad Panic 5 Audible Keypad Panic 6 Keypad Auxiliary 1 7 Keypad Auxiliary 2 8 Multi Keypad Tamper Press the key on the numeric keypad that corresponds to the feature you wish to enable disable When an LED is on a feature is enabled when off the feature is disab...

Page 11: ... will prevent successful connection to the central station L 1 ACCOUNT CODE FOR PHONE 1 6 numerical The account code sent when Phone 1 is dialed is programmed in location 1 Program a A10 in the segment immediately after the last digit of the account code If the account code is 6 digits long program all 6 segments L 2 COMMUNICATOR FORMAT FOR PHONE 1 1 numerical Location 2 contains the communicator ...

Page 12: ...at should be reported to Phone 1 If no events should be reported to Phone 1 both locations should be programmed as 0 disabling all options 4 EVENTS REPORTED TO PHONE 1 2 feature select Segment 1 1 Alarms and Alarm Restores 2 Opening and Closings 3 Zone Bypass and Bypass Restores 4 Zone Trouble and Trouble Restores 5 Power Fail Low Battery Power Restore and Low Battery Restore 6 Bell Cut Telephone ...

Page 13: ...ns are reported to Phone 2 If dual or split reporting is not desired location 10 and location 11 should be left at the factory default of 0 If multi reporting or split reporting is desired and the split is based on the event type such as alarm open close etc location 10 should be used to select only those events that should be reported to Phone 2 and location 11 should be left at the factory defau...

Page 14: ...pts to Phone 2 then repeating until the total number of attempts designated in Segment 1 is completed REPORTING EVENTS TO PHONE NUMBER 3 Phone 3 can be used for a third receiver to multi report or split report events Phone 3 has two programming locations that are used to select which events are reported to this phone number Location 16 is used to select which events are reported to Phone 3 and Loc...

Page 15: ...e viewed from the keypad when Off 8 On enables call back at auto test interval L 22 DOWNLOAD CALL BACK NUMBER 20 numerical If a telephone number is programmed into this location and Require Callback is enabled in location 21 the control panel will hang up for approximately 36 seconds ensuring that the calling party has disconnected and then call back If tone dialing is desired program an 15 in the...

Page 16: ... programmed to be one of thirty different zone types configurations Zone types 17 20 can be used for wireless or hardwired zones using European double EOL configuration The default zone types are listed below These zone types can be customized by programming locations 110 169 DATA DESCRIPTION OF DEFAULT ZONE TYPES 1 DAY ZONE Instant when system is armed trouble zone when system is disarmed 2 24 HO...

Page 17: ...an instant alarm regardless of the armed state of the control panel It will display on the keypad and activate the keypad sounder 22 LOW TEMP DETECTION Creates an instant silent alarm regardless of the armed state of the control panel It will display on the keypad and activate the keypad sounder 23 HIGH TEMP DETECTION Creates an instant silent alarm regardless of the armed state of the control pan...

Page 18: ...Partition 5 7 Partition 7 2 Partition 2 4 Partition 4 6 Partition 6 8 Partition 8 L 31 ZONES 25 32 ZONE TYPE 8 numerical Location 31 contains the Zone Type for zones 25 32 Segment 1 is for zone 25 Segment 8 is for zone 32 Default Zone Types are found in the table on page 16 To customize a Zone Type see page 28 32 PARTITION SELECT ZONES 25 32 8 feature select Location 32 is used to select the parti...

Page 19: ... siren driver enabled 2 On if siren sounds for expander trouble required for UL installations 3 On for Immediate Restore by zone Off for zones to restore only when siren is off 4 On if Dynamic Battery Test performed at arming Off if performed at disarming See location 40 5 On if Battery Missing Test is performed every 12 seconds 6 On if Manual Bell Test performed during r 4 4 test function 7 On if...

Page 20: ...conds 0 no power up delay Segment 4 Siren Time in minutes 1 254 minutes Segment 5 Telephone Line Cut delay in seconds 0 255 seconds 0 no TLM Segment 6 Cross Zone time in minutes 0 255 minutes 0 no cross zoning Segment 7 Chime time in 50 mS 1 20th second increments from 0 12 seconds 0 follows zone 255 latched Segment 8 Dial delay in seconds 15 255 seconds Segment 9 Fire Alarm Verification time in s...

Page 21: ... 41 the last 2 digits will be ignored If the duress code is programmed it will work for all partitions 45 AUXILIARY OUTPUT 1 4 PARTITION SELECTION 4 feature select Location 45 is used to select which partition s the events must occur in before the output will activate Location 45 has 4 segments Segment 1 corresponds to output 1 and Segment 4 corresponds to output 4 Segment 1 Aux 1 Segment 2 Aux 2 ...

Page 22: ... Start 53 Armed Away 16 Autotest 35 Fail To Communicate 54 Armed Stay 17 Alarm Memory 36 Telephone Line Fault 55 Aux Comm Fail 18 Entry 37 Program Mode 56 CP 01 Progress Annunciation Events 49 50 require one or more of the following to operate NX 408E NX 416E NX 448E wireless receivers or NX 1700E card reader If set to follow condition these events will be 1 second Note When Event 48 is programmed...

Page 23: ...er ID is 15 the 4 2 lower digit will be F and if the zone ID or user ID is 16 the 4 2 digit will be 1 See Appendix 4 on page 53 NOTE If Segments 2 8 are left as 0 unprogrammed they will follow the Segment 1 selection If Segment 1 is left as 0 and the feature is enabled in Location 23 the NX 8V2 will report A 56 RESTORE COMMUNICATOR CODE 8 numerical Location 56 contains the event code for any zone ...

Page 24: ... LOW BATTERY RESTORE COMMUNICATOR CODE 4 numerical Location 69 contains the digits for a 4 2 format that will be sent if Low Battery Reporting is enabled Segments 1 2 contain the digits of the Low Battery Reporting Segments 3 4 contain the digits of the Low Battery Restore Refer to the box on page 23 70 AUX POWER OVERCURRENT RESTORE COMM CODE 4 numerical Location 70 contains the digits for a 4 2 f...

Page 25: ...is enabled Segment 1 contains the digit for the Cancel Communicator Reporting Refer to the box on page 23 84 87 RESERVED LOCATIONS 88 109 ARE FOR PROGRAMMING DIFFERENT ACCOUNT CODES AND OR FEATURES FOR EACH PARTITION IF A LOCATION IS LEFT UN PROGRAMMED THE FEATURE FOR PARTITION 1 AND ACCOUNT CODE FOR THE PHONE NUMBER WILL BE USED 88 ACCOUNT CODE FOR PARTITION 1 6 numerical Location 88 contains the...

Page 26: ... features for partition 1 will be used 97 PARTITION 4 ENTRY EXIT TIMERS 6 numerical Location 97 is used to enter in seconds the Entry and exit times There are 2 separate entry and exit times Valid entries are 10 255 seconds If all segments are A0 the entry and exit times for partition 1 will be used Segment 1 Entry time 1 Entry time that will be used when a Delay 1 zone type initiates an entry del...

Page 27: ...the features for partition 1 will be used 106 PARTITION 7 ENTRY EXIT TIMERS 6 numerical Location 106 is used to enter in seconds the Entry and Exit times There are 2 separate entry and exit times Valid entries are 10 255 seconds If all segments are A0 the entry and exit times for partition 1 will be used Segment 1 Entry Time 1 Entry time that will be used when a Delay 1 zone type initiates an entr...

Page 28: ... Type is force armable 8 On if Zone Type is entry guard Segment 3 1 On enables Fast Loop Response 50mS Off 500mS 2 On enables Double End Of Line Tamper zone Mainly used for tamper on wireless zones 3 On enables Trouble Reporting zone Day zone and Fire zones 4 On if Zone Type is a Cross Zone 5 On enables Dialer Delay zone See location 40 page 20 6 On if Zone Type will swinger shutdown See location ...

Page 29: ...ERISTIC SELECT 5 feature select Use Zone Type Characteristic Selections described in Location 111 page 28 126 ZONE TYPE 9 ALARM EVENT CODE 1 numerical Location 126 contains the event code sent for a Contact ID or SIA report The desired event code should be chosen from the list on page 50 The zone ID will be that zone that is in alarm If 4 2 format is being used refer to Location 110 on page 28 for...

Page 30: ...RACTERISTIC SELECT 5 feature select Use Zone Type Characteristic Selections described in Location 111 page 28 146 ZONE TYPE 19 ALARM EVENT CODE 1 numerical Location 146 contains the event code sent for a Contact ID or SIA report The desired event code should be chosen from the list on page 50 The zone ID will be that zone that is in alarm If 4 2 format is being used refer to Location 110 on page 2...

Page 31: ...elect Use Zone Type Characteristic Selections described in Location 111 page 28 164 ZONE TYPE 28 ALARM EVENT CODE 1 numerical Location 164 contains the event code sent for a Contact ID or SIA report The desired event code should be chosen from the list on page 50 The zone ID will be that zone that is in alarm If 4 2 format is being used refer to Location 110 on page 28 for details 165 ZONE TYPE 28...

Page 32: ...DE 10 10 10 10 10 10 _ _ _ _ _ _ L 8 13 PHONE 2 REPORTING FORMAT 0 _ 9 13 PHONE 2 DIAL ATTEMPTS BACKUP CONTROL 8 0 _ _ 10 13 PHONE 2 SELECTING EVENTS TO REPORT TO PHONE 2 Segment 1 Circle Numbers To Program Segment 2 Circle Numbers To Program 1 Alarms and Restores 2 Open Close 3 Bypass 4 Zone Trouble 5 Power Trouble AC Failure or Low Battery 6 Siren Telephone Fault 7 Test Reports 8 Program Downloa...

Page 33: ...panel 5 Lock out local programming 6 Lock out communicator programming 7 Lock out download section 8 Enables callback at autotest interval L 22 15 CALLBACK PHONE NUMBER 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ L 23 15 PARTITION 1 FEATURE SELECTION Segment 1 Circle Numbers To Program 1 Quick Arm 2 Re Exit 3 Auto Bypass 4...

Page 34: ... 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 L 31 18 ZONES 25 32 ZONE TYPES 6 6 6 6 6 6 6 6 _ _ _ _ _ _ _ _ 32 18 ZONES 25 32 PARTITION SELECTION Segment 1 Zone 25 thru Segment 8 Zone 32 Segments 1 2 3 4 5 6 7 8 Partition 1 Partition 2 Partition 3 Partition 4 Partition 5 Partition 6 Partition 7 Partition 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 ...

Page 35: ... report enabled 3 Low Battery report enabled 4 Auxiliary power over current report enabled 5 Siren supervision report enabled 6 Telephone Line Cut report enabled 7 Ground Fault Detection report enabled 8 Expander trouble report enabled Segment 4 Circle Numbers To Program 1 Failure To Communicate report enabled 2 Log Full report enabled 3 Autotest report enabled 4 Start and End Programming report e...

Page 36: ...igits 2 Requires valid user code entry for r 9 8 and r 9 9 functions to work 3 Enable Auto Cancel Abort 4 Enable Walk Test Mode 5 Enable Auto Force Arming with keyfob or keyswitch 6 8 Reserved L 42 21 GO TO PROGRAM CODE 9 7 1 3 0 0 _ _ _ _ _ _ 43 21 GO TO PROGRAM CODE PARTITION AND AUTHORIZATION Segment 1 Circle numbers to program 1 Reserved 2 Enables Go To Program Code as an arm only code 3 Enabl...

Page 37: ...2 AUTOTEST CONTROL Segment 1 Program a 1 if the interval is hours a 0 if in days Add a A2 to suppress the daily test or a A3 to suppress the hourly test 1 Segment 2 Program the autotest interval from 1 255 days or hours 24 Segment 3 Program the autotest report in 24 hour time format 2 Segment 4 Program the autotest report time minutes after the hour 0 52 22 OPENING TIME Segment 1 Program the hour ...

Page 38: ...LY Segment 1 Partition 1 Tamper Code 0 _ Segment 2 Partition 2 Tamper Code 0 _ Segment 3 Partition 3 Tamper Code 0 _ Segment 4 Partition 4 Tamper Code 0 _ Segment 5 Partition 5 Tamper Code 0 _ Segment 6 Partition 6 Tamper Code 0 _ Segment 7 Partition 7 Tamper Code 0 _ Segment 8 Partition 8 Tamper Code 0 _ 59 23 TROUBLE COMMUNICATOR CODE SLOW SPEED FORMATS ONLY Segment 1 Partition 1 Trouble Code 0 ...

Page 39: ...DE Segment 1 Partition 1 Closing Code 0 _ Segment 2 Partition 2 Closing Code 0 _ Segment 3 Partition 3 Closing Code 0 _ Segment 4 Partition 4 Closing Code 0 _ Segment 5 Partition 5 Closing Code 0 _ Segment 6 Partition 6 Closing Code 0 _ Segment 7 Partition 7 Closing Code 0 _ Segment 8 Partition 8 Closing Code 0 _ 79 25 AUTOTEST COMMUNICATOR CODE 0 0 _ _ 80 25 RECENT CLOSING AND EXIT ERROR 0 0 _ _ ...

Page 40: ... Segment 5 RESERVED 94 26 PARTITION 3 ENTRY EXIT TIMERS Segment 1 Entry Time 1 0 _ Segment 2 Exit Time 1 0 _ Segment 3 Entry Time 2 0 _ Segment 4 Exit Time 2 0 _ Segment 5 6 RESERVED 95 26 PARTITION 4 ACCOUNT CODE 10 10 10 10 10 10 _ _ _ _ _ _ 96 26 PARTITION 4 FEATURE AND REPORTING SELECTION Segment 1 1 Quick Arm 2 Re Exit 3 Auto Bypass 4 Silent Panic 5 Audible Panic 6 Auxiliary 1 7 Auxiliary 2 8...

Page 41: ...CCOUNT CODE 10 10 10 10 10 10 _ _ _ _ _ _ 102 27 PARTITION 6 FEATURE AND REPORTING SELECTION Segment 1 1 Quick Arm 2 Re Exit 3 Auto Bypass 4 Silent Panic 5 Audible Panic 6 Auxiliary 1 7 Auxiliary 2 8 Multi Keypress Tamper Segment 2 1 LED extinguish enable 2 Require user code for bypassing zones 3 Bypass sounder alert 4 AC power low battery sounder alert 5 Enables bypass toggle 6 Enables silent aut...

Page 42: ...code for bypassing zones 3 Bypass sounder alert 4 AC power low battery sounder alert 5 Enables bypass toggle 6 Enables silent auto arm 7 Enables auto instant 8 Reserved Segment 3 1 Open Close 2 Bypass 3 Restore 4 Trouble 5 Tamper 6 Cancel 7 Recent Closing 8 Exit Error Segment 4 1 Late to Close Early to Open 2 8 Reserved Segment 5 RESERVED 109 27 PARTITION 8 ENTRY EXIT TIMERS Segment 1 Entry Time 1...

Page 43: ...T CODE 0 __ 123 ZONE TYPE 7 CHARACTERISTIC SELECT 2 0 78 0 0 __ __ __ __ __ 124 ZONE TYPE 8 ALARM EVENT CODE 1 __ 125 ZONE TYPE 8 CHARACTERISTIC SELECT 1 13 378 0 0 __ __ __ __ __ 126 ZONE TYPE 9 ALARM EVENT CODE 7 __ 127 ZONE TYPE 9 CHARACTERISTIC SELECT 6 1245 5678 0 0 __ __ __ __ __ 128 ZONE TYPE 10 ALARM EVENT CODE 2 __ 129 ZONE TYPE 10 CHARACTERISTIC SELECT 24 5 78 0 0 __ __ __ __ __ 130 ZONE...

Page 44: ...7 1257 5678 0 0 __ __ __ __ __ 164 ZONE TYPE 28 ALARM EVENT CODE 7 __ 165 ZONE TYPE 28 CHARACTERISTIC SELECT 6 12457 5678 0 0 __ __ __ __ __ 166 ZONE TYPE 29 ALARM EVENT CODE 5 __ 167 ZONE TYPE 29 CHARACTERISTIC SELECT 457 125 5678 1 0 __ __ __ __ __ 168 ZONE TYPE 30 ALARM EVENT CODE 7 __ 169 ZONE TYPE 30 CHARACTERISTIC SELECT 5 1245 5678 1 0 __ __ __ __ __ 170 205 RESERVED 206 DAYS OF THE WEEK AU...

Page 45: ...NX 8V2 Control 45 ZONE WORKSHEET 1 25 2 26 3 27 4 28 5 29 6 30 7 31 8 32 9 33 10 34 11 35 12 36 13 37 14 38 15 39 16 40 17 41 18 42 19 43 20 44 21 45 22 46 23 47 24 48 ...

Page 46: ... these features ADialer Delay must be enabled in the ACharacteristic Select of locations 110 169 Zone Types Loc 41 pg 20 Auto Test This feature will cause the panel to call the central station to report a communicator test at a specified interval Loc 51 pg 22 Auxiliary Outputs The NX 8V2 has 4 programmable outputs that can be used to activate relays LED s etc See the terminal description on pg 6 a...

Page 47: ...nders The expansion device number that will report can be found on page 52 Loc 37 pg 19 Fail to Communicate The NX 8V2 will illuminate the Service LED if a report fails to reach the central station If enabled when the next report is successfully communicated a Fail to Communicate code will be reported Loc 37 pg 19 Fire Alarm Verification When enabled the NX 8V2 will verify a Fire alarm by requirin...

Page 48: ... restart the exit delay for a quick exit without disarming the system by pressing the Exit key while the system is armed Loc 23 pg 15 Shutdown When enabled the keypads will turn off all LED s except the Power LED and not accept keypresses Loc 21 pg 15 Siren Blast For Arming The NX 8V2 can be programmed to give a one second siren blast when the panel is armed at the end of the exit delay or when th...

Page 49: ...any time during this mode enter a user code Otherwise the AWalk Test Mode will automatically exit after 15 minutes Loc 41 pg 20 Wireless Sensor Missing Low Battery The NX 8V2 will send a report to the central station when a wireless sensor has detected a low battery or has not reported to the receiver The Service LED will illuminate when either condition exists Loc 37 pg 19 Zone Activity Monitor T...

Page 50: ...F KEYPAD AUXILIARY 1 110 FA KEYPAD AUXILIARY 2 100 MA KEYPAD PANIC audible 120 PA KEYPAD PANIC silent 121 HA KEYPAD TAMPER 137 TA LOW BATTERY device number 309 YT LOW BATTERY RESTORE device number 309 YR MANUAL TEST 601 RX OPEN user number 401 OP RECENT CLOSE user number 401 CR RF SENSOR LOST zone number 381 T RF SENSOR RESTORE zone number 381 R SENSOR BATTERY RESTORE zone number 384 XR SENSOR LOW...

Page 51: ... Alarm 17 WA Water Alarm 18 QA Emergency Alarm 19 SA Sprinkler Alarm 20 ZA Freeze Alarm 21 KH High Temp Alarm 22 FA Manual Fire Alarm The NX 8V2 has the ability to report Ademco Contact ID transmissions Each report in Contact ID consists of an Event Code and a Zone ID The zone ID is the zone that created the alarm The event code will come from the chart below and be programmed in the zone type eve...

Page 52: ... 250 251 252 253 254 255 HARDWIRE EXPANDER NX 216E Starting zone number Expander reported Zone 09 All switches off 22 Zone 09 Switch 1 on 23 Zone 17 Switch 2 on 16 Zone 25 Switches 1 2 on 17 Zone 33 Switch 3 on 18 Zone 41 Switches 1 3 on 19 REMOTE POWER SUPPLY NX 320E WIRELESS RECEIVER NX 448E Switch Setting Address Switch Setting Expander reported All switches off 84 All switches off 35 Switch 1 ...

Page 53: ...ents 2 8 are left as 0 unprogrammed they will follow the Segment 1 selection If Segment 1 is left as 0 and the feature is enabled in Location 23 the NX 8V2 will report A ZONE ZONE ZONE USER HEX USER HEX USER HEX 1 1 34 4 67 7 2 2 35 5 68 8 3 3 36 6 69 9 4 4 37 7 70 A 5 5 38 8 71 B 6 6 39 9 72 C 7 7 40 A 73 D 8 8 41 B 74 E 9 9 42 C 75 F 10 A 43 D 76 1 11 B 44 E 77 2 12 C 45 F 78 3 13 D 46 1 79 4 14...

Page 54: ...t the equipment from the telephone line to determine if it is the customers equipment that is not functioning properly If the problem is with the device the customer shall discontinue use until it is repaired EQUIPMENT INFORMATION Manufacturer Of Connecting Equipment GE SECURITY INC FCC Registration Number US GCQAL01BNX V2 RINGER EQUIVALENCE 0 1 B XXI INDUSTRY CANADA INFORMATION NOTICE The Industr...

Page 55: ...e networks in the countries marked with a check and may have interworking problems with the countries that are not checked Due to the inherent differences in the individual PSTNs certain software settings may need to be adjusted on a country to country basis If it is desired to use this equipment on a network other than the one on which it was originally installed you should contact your equipment...

Page 56: ...e Downloading shall not be used on UL listed systems For residential burglary applications the maximum entry and exit delay times shall be 45 and 60 seconds respectively The exit delay time shall not exceed 60 seconds for commercial burglar alarm applications The keyswitch options shall not be used The Telephone Line Monitor shall be enabled The Telephone Line Cut delay shall not exceed 90 seconds...

Page 57: ...H 1 Amp 400 mA 34 AH 1 Amp 200 mA 17 AH 1 Amp Calculations based on three 17 Amp batteries K IMPORTANT If separate power supplies are necessary to accommodate additional devices safety standards require that each power supply be prominently marked with adequate instructions for removing all power from the unit Dispose of used batteries according to the manufacturer s instructions and or local gove...

Page 58: ...g Entry Delay s Entry 1 Delay 24 1 30 30 240 sec Entry 2 Delay 24 3 30 30 240 sec Abort Window for Non Fire Zones Dialer Delay 40 8 30 Enabled may be disabled by zone zone type Abort Window Time for Non Fire Zones Dialer Delay 40 8 30 15 45 sec NOTE Combined Abort window and Entry Delay must not exceed 1 minute Abort Annunciation This feature is non programmable in the panel Flashing Cancel LED go...

Page 59: ...SYSTEM NOTES ...

Page 60: ...lectable 50mS or 500mS OPERATING TEMPERATURE 32 to 120 degrees F LED KEYPAD Current Draw 130 mA max Zones Normal w o Sounder 55 mA Dimensions 6 4 Wide 4 0 High 1 1 Deep NX148E LCD KEYPAD Current Draw 110 mA max w o Sounder 75 mA Dimensions 6 4 Wide 5 3 High 1 0 Deep METAL ENCLOSURE DIMENSION 11 25 Wide 11 25 High 3 50 Deep SHIPPING WEIGHT 9 lbs Main 800 727 2339 Technical Support 888 437 3287 Outs...

Reviews: