36
NX-8V2 Control
LOC
PG
DESCRIPTION
DEFAULT
PROGRAM DATA
L
39 20 KEYPAD
SOUNDER
Segment 1 (Circle numbers to program)
1 = Keypad sounds for Telephone Line Cut when in the Armed state.
2 = Keypad sounds for Telephone Line Cut when in the Disarmed state.
3 = Keypad sounds upon AC Power Failure.
4 = Keypad sounds upon Low Battery Detection.
5 = Keypad sounds during Cross Zone Trip Time.
6 = Keypad sounds for Tamper Alarm.
7 = Reserved.
8 = Keypad sounds for expander trouble (required for UL).
L
40 20 SYSTEM
TIMERS
Segment 1 Dynamic Battery Test duration (0-255 minutes)
0
_
Segment 2 AC Failure report delay (0-255 minutes)
5
_
Segment 3 Power Up Delay (0-60 seconds)
60
_
Segment 4 Siren Time (1-254 minutes)
8
_
Segment 5 Telephone Line Cut delay (0-255 seconds)
0
_
Segment 6 Cross Zone Time (0-255 minutes)
5
_
Segment 7 Chime Time in 50 mS increments (0-255)
3
_
Segment 8 Dialer delay (15-255 seconds)
30
_
Segment 9 Fire Alarm Verification Time (120-255 sec.)
0
_
Segment 10 Listen-In Time (0-255 seconds)
0
_
Segment 11 Zone Monitor Timer (0-255 Days)
0
_
Segments 12 – 14 Reserved
41 20 SPECIAL
FEATURES
Segment 1 (Circle numbers to program)
1 = Enables 6-digit code option. All arm/disarm/Go To Program codes require six digits
2 = Requires valid user code entry for [
r
]-[9]-[8] and [
r
]-[9]-[9] functions to work.
3 = Enable Auto Cancel / Abort.
4 = Enable Walk-Test Mode.
5 = Enable Auto Force-Arming with keyfob or keyswitch
6-8 = Reserved.
L
42
21 GO TO PROGRAM CODE
9-7-1-3-0-0
_ _ _ _ _ _
43
21 GO TO PROGRAM CODE PARTITION AND AUTHORIZATION
Segment 1 (Circle numbers to program)
1
=
Reserved.
2 = Enables "Go To Program Code" as an arm only code.
3 = Enables "Go To Program Code" as an arm only after closing.
4 = Enables "Go To Program Code" as a master arm/disarm code (can change user codes)
5 = Enables "Go To Program Code" as an arm/disarm code.
6 = Enables "Go To Program Code" to bypass zones.
7 = Enables "Go To Program Code" opening and closing reports.
8 = Reserved.
Segment 2 (Circle numbers to program)
1 = Enables "Go To Program Code" for partition 1
2 = Enables "Go To Program Code" for partition 2
3 = Enables "Go To Program Code" for partition 3
4 = Enables "Go To Program Code" for partition 4
5 = Enables "Go To Program Code" for partition 5
6 = Enables "Go To Program Code" for partition 6
7 = Enables "Go To Program Code" for partition 7
8 = Enables "Go To Program Code" for partition 8
L
44
21 DURESS CODE
15-15-15-15-15-15
_ _ _ _ _ _
45
21 AUXILIARY OUTPUTS 1-4 PARTITION SELECTION
Segments
1 2 3
4
1 = Partition 1
2 = Partition 2
3 = Partition 3
4 = Partition 4
5 = Partition 5
6 = Partition 6
7 = Partition 7
8 = Partition 8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8