XXIV.
ANSI / SIA
CP-01 REQUIREMENTS
T
o
meet SI
A
C
P
-01 req
u
irem
en
ts –
•
Minim
u
m S
ys
te
m
Req
u
ire
m
en
ts
: 1 co
ntr
o
l pa
nel; 2 k
e
yp
a
d
s (
o
r 1 ke
yp
ad
per
partiti
on
for
mul
ti-par
titi
one
d s
ystems
)
•
Remo
te ar
min
g
shall N
O
T
be e
n
abled i
n
SI
A
cla
ssified i
n
st
allati
ons.
•
Of
f-pre
mise tra
n
smiss
ion mu
st
be
in the
SI
A
fo
rmat.
•
The
A
b
or
t
w
indo
w
and Entr
y D
ela
y
m
u
st
not
e
xceed 1
min
u
te.
•
C
A
U
T
IO
N
–
A
c
all
w
aiting canc
el on a
no
n-call
w
aiting line
w
ill
pre
ven
t suc
ces
sful c
o
n
n
ecti
on
to the ce
ntral s
tation
.
CP-01 F
eat
ure
Descrip
tion
Feat
ure Descri
p
tion
as sho
w
n in ma
nual
Program
Loc
Seg / Opt
Fact
or
y
Defaul
t
CP-01 Re
quire
d
Settin
g
Ex
it T
ime
Ex
it 1 Delay
24
2
60
45 – 240 sec.
Ex
it 2 Delay
24
4
60
45 – 240 sec.
Progress Annunc
ation / Disable
– for Silent Exit
Silent Key
p
ad
Option
9 3
2
All annunciators enabled
Allow
ed
(individual key
pa
ds ma
y be disabled)
Exit Time Restart
This feature is
no
n-prog
rammable
in the panel.
Enabled
Auto Sta
y Arm o
n Unvacated Pre
m
ises
Auto B
ypass
23
1 / 3
Enabled Enabled
Exit Time and Pr
ogress
Annunciation / Disable
– for Remo
te Arm
This feature is no
n-prog
rammable
in the panel. --
Exit ti
me and pro
gress are al
w
a
ys
enabled.
Enabled (ma
y be
disabled for re
m
ote arming)
E
nt
ry D
el
a
y(
s)
E
nt
ry
1 D
el
a
y
24
1
30
30 – 240 sec.
Entry
2
Dela
y
24
3
30
30 – 240 sec.
Abort Windo
w
– for Non
-Fire
Zo
nes
Dialer Dela
y
40
8
30 Enabled
(ma
y b
e disabled b
y zone/ zone t
ype)
Abort Windo
w
Ti
me
– for Non
-Fire
Zo
nes
Dialer Dela
y
40
8
30
15 – 45 sec.
NOT
E
:
Com
b
ined
A
bort
window
and E
n
tr
y
Delay m
u
st
not
exceed 1
m
inut
e
.
Abort Annunciation
This feature is no
n-prog
rammable
in the panel
. --
Flashing Cancel LED
goes off
w
h
en disarming.
Enabled
Cancel Annunciation
Cancel
23
3 / 6
Enabled Enabled
Duress Featu
re
Duress
44
Disabled
Disabled
Cross Zoning
2 Trips on C
ross Zone
37
5 / 4
Disabled
Required
Ke
ypad soun
ds on Cross Zone
tri
p
39
5
Disabled
Zone T
ype
Char
acteristic
111
3 / 4
Disabled
Programma
ble C
ross Zoning Tim
e
Cross Zone
Time
40
6
5 minutes
Allow
ed
Sw
inge
r Shutdo
w
n
Sw
inge
r Shutdo
w
n
Count
38
n/a
Enabled for 1 t
rip
For all non-fir
e zones, shut do
w
n
at 1–2 trips
Sw
inge
r Shutdo
w
n
Disable
Sw
inge
r Shutdo
w
n
Count
38
n/a
Enabled for 1 t
rip
Allow
ed
Fire Alarm Verification
Fi
re Alarm Verification Time
40
9
Disabled Required
(depen
ds
on panel & sensors)
Call Waiting Cancel
Must be prog
ram
m
ed as part of th
e
phone numbe
r
0
n/a
n/a
Required
(depen
ds on user phon
e line)
Default Chang
es (fro
m
p
rior versions):
Recent Closing
23
3 / 7
Enabled
Ex
it Erro
r
23
3 / 8
Enabled
Power
Up
Dela
y
40
3
60 sec.
IM
P
O
RT
ANT
N
O
TE
:
UL requir
e
m
ents
take
priority over SIA
require
m
ents.