Hardware Installation
Digiplex IV User Manual
12
1034169B / December 2003
9)
Digiplex IV systems are shipped preconfigured. If you need to verify or change the termination,
signal format settings, or addressing for the system, refer to appendixes A, B, and C.
10)
Connect the KTD-446 power supply to the KTD-440 chassis, then to a power source. See Figure 5.
Power source
115 VAC
power cord
KTD-446
5 VDC
power cord
KTD-440
Figure 5. KTD-440 power connections
3.2 I
NSTALLING THE
KTD-440G C
HASSIS
CAUTION:
Complete all instruction steps before supplying power to the unit.
1)
Mount the KTD-440G chassis into a 19-inch (48.26 cm) rack directly under the KTD-441-2,
KTD-441-3, or KTD-440N chassis. Refer to your system configuration in
Appendix G. System
Configurations.
2)
Mount a KTD-446 power supply near the KTD-440G chassis.
3)
Connect the ribbon cables between the KTD-440G and other chassis. See Figure 6 and refer to
your system configuration in
Appendix G. System Configurations
.
OUTPUT PORT 1
PORT 2
PORT 3
PORT 1
PORT 2
PORT 3
PORT 4
PORT 5
PORT 6
PORT 7
PORT 8
Figure 6. KTD-440G ribbon cable connections