Always turn on the water chiller before turning on the machine.
CAUTION
Make sure to add water to the water chiller before turning on the machine.
NOTE
De-ionized water is recommended as the coolant. Propylene glycol can
be used as an anti-freeze agent.
The coolant used with the water chiller should have the following properties:
•
Good heat conduction and low viscosity
•
Anti dirt forming
•
Low
electric
conductivity
< 2
μ
S/cm
•
Non-corrosive
SmartCut X380 User Manual
- 21 -