Page 4 - 12
Installation
Orca 1600 Operation and Maintenance Manual
© GBC Films Group February 2001
b) Set the main air in pressure to 70 pounds per
square inch (psi) (500 kPa) by turning the air
regulator knob.
100
R e g u la to r
k n o b
T he u pper m ain roller and the up per pull
roller should b e in the raised position.
IN F O R M A T IO N
c) Close the control side cabinet and secure with the
factory bolts.
4.9 Installing levelers
Leveling of the machine is a customer option. If
you choose not to level the laminator and you encounter
output problems, please level the machine and try your
application again before calling for technical support.
Resting the laminator on the leveling pads will prevent the
machine from rolling during set up, operation or servicing.
Tools required
• ( 1 ) 1/2 in. open end wrench
• ( 1 ) 7/8 in. open end wrench
• Four leveling pads
( from the accessory pack )
a) Be sure that the machine is placed where you
want it to rest.
b) Secure the four leveling pads onto the four foot
bolts.
c) Use the 1/2 in. wrench on the foot bolt and the
7/8 in. wrench on the leveling pads and tighten
them together.
7/8 W renc h