Page 4 - 9
Installation
Orca 1600 Operation and Maintenance Manual
© GBC Films Group February 2001
4.6 Accessory pack
Once the Orca 1600 Laminator has been
unpacked and moved into final position, open the accessory
pack and verify the contents.
Accessory Pack contents
• One T-handle allen wrench ( 475-200 )
• One Zippy knife ( 475-620 )
• One Terry clothe towel ( 475-950 )
• One Operators manual ( 930-061 )
• One roll masking tape ( 475-000 )
• Two Polyurethane O-rings ( 480-005 )
• One strain relief for main power ( 175-201 )
• One rubber cement pad ( 930320 )
• Four fuses, 3.0A ( 186-200 )
• Four leveling pads ( 475-100 )
If you are missing any of the items listed above,
contact your local service technician or sales
representative.
Contacts:
GBC Parts ( 800 ) 790 - 7787
GBC Europe parts 33 - 45 - 535 - 7676
4.7 Electrical Connection
The Orca 1600 laminator requires 220 ~ 240
VAC electrical power for proper operation. The power
supply may be either single phase or three phase ( five
wire or four wire ). For single-phase power, a 55 amp
service is required and for three-phase power, 25 amps
per phase is required.
The Orca 1600 requires the electrical power cord
to be wired directly to the line terminal block located within
the control side cabinet.
Before the machine is installed, a qualified
electrician must route the proper wiring to the location
where the machine will be stationed. The machine then
can be connected to the power supply by a qualified
electrician following one of the three instructions listed
below.
ELECTRICAL
S H O C K
Only a qualified electrician should connect
power to the laminator. You can be severely
shocked, electrocuted or cause a fire if
power is improperly applied.
4.7.1 Preparation
a) Ensure the power at the junction box is in the
OFF position. Use a voltage meter to verify.