3.
Fasten crimper to work surface
before use
(to avoid damage to
machine or personal injury because
an unsecured machine can fall).
• Position crimper so that mounting holes
are approximately 7" to 8" from the
edge of the work surface.
• Mark the drilling location using the
mounting holes as a guide (see illustra-
tion below).
• Drill two 5/16" diameter holes.
• Use mounting holes or clamps to fasten
stand to work surface.
4.
Attach pump to crimper.
• Place pump near crimper.
• Connect hose assembly to the pump
port (3/8" NPT threads). Pipe sealant
may be used to seal connection.
(For
best connection, use Gates’ Quick
Disconnect couplings, G95311-0606
and G95321-0606, sold separately.)
• Connect opposite end to the adapter
on crimper.
5.
Check pump oil level.
• Pump comes with oil in reservoir.
• Check proper oil level per pump
operating manual instructions or the
Maintenance Section (p. 14) of this
manual.
6.
Connect pump to power outlet.
• For 115V connection, plug power cord
into a properly grounded and rated circuit
(see inside cover for circuit requirements).
• For vehicle battery connection, see
pump operating manual.
Edge of
work
surface
(2)
5
/
16
" diameter holes
7
1
/
2
"
11"
clamps
mounting holes
To avoid damage to
the machine or injury
to you, ALWAYS fasten
the crimper to the work
surface before you attempt to crimp.