• Make sure cylinder is locked into posi-
tion by placing lock pin into hole on
top of cylinder.
7.
Begin the crimp.
• Start pump by steadying hose with one
hand while pressing and holding
the power “on” switch with the other
hand, which extends the ram (see pump
operation manual for switch location).
• When light comes on and buzzer
sounds,
immediately
release the power
“on” switch. Crimp is now complete.
NOTE
: If light and buzzer become faint
or do not work, the controller batteries
may need replacement. See Maintenance
Section (p. 14).
8.
Remove hose assembly.
• While holding hose, lightly lift bottom
of die set to release hose assembly.
• Remove hose assembly.
Serious injury and/or crimper
damage can result if the cylinder
is not locked in its crimp position.
IMPORTANT
lock pin
Keep away from all moving parts!
If bodily contact with a moving part
occurs, immediately release the pump
power “on“ switch.
Incorrect
Correct
CAUTION