ELECTRONIC DIAL INDICATOR
This crimper has a dial indicator to visually show when the operator needs to stop
hydraulic flow to the head. It is advisable that you get use to the dial indicator before
calibrating. This is usually done by crimping the same specification assembly many
times and note the difference in COD with each assembly. The calibration process is
trial and error, with the goal of being confident that you can repeatedly crimp to 1.000”
/- .003” using the dial indicator.
INSERT PN 74827131; PARTNO 78863 DIES INTO HEAD
Unpack 33 Dies from Container. Use Quick Change Tool to load die set in to machine.
NOTE:
Refer to Owners Manual for details.
ADJUST DIAL INDICATOR KNOB
Adjust Dial indicator Knob to number 0123. This number is the factory calibration
number for a 1” inch crimp.
CRIMP 8G MEGACRIMP
®
While holding the thread end of an 8G MegaCrimp
®
coupling, insert coupling into
crimper so that ferrule is 1/8” from front edge of die shoe.
GC32
TM
FLEX
CALIBRATION PROCEDURE
70
DOWNLOAD THE ECRIMP APP OR GO TO WWW.GATES.COM/ECRIMP
GENERAL
SWA
GING
GC32-XD/FLEX
GC96
PC707/SC32
GC16XD
MC 4-20 DD & PS
PO
WER STEERING
GATES
CALIBRATION & ADJUSTMENT PROCEDURES