CONNECTING THE CYLINDER

(a) Place the gas filled cylinder into the back of the heater
(b) Clip on the gas regulator to the gas cylinder (fit for 15kg gas cylinder)
(c) Turn the regulator on.
(d) Where the regulator is not supplied please contact your gas dealer to advise of

correct type for the gas cylinder being used.

(e) To avoid of twisting the hose,please make sure to connect the hose with

regulator and heater smoothly

(f) The length of hose not less than 50cm,PVC or Rubber type, comply with

BS3212-Class 2/EN1763-1-Class 3 / EN16436-1:2014+A3:2020

(g) IMPORTANT TEST FOR LEAKS:
This must be carried out in a well-ventilated area, free from naked flames and any
other sources of ignition. With the regulator connected to the cylinder turn on
the regulator control. Brush all hose connections, pipe connections to the valve
and gas cylinder valve with a 50:50 solution of detergent and water. A stream of
bubbles forming indicates a leak. If a leak is found turn off at the regulator and
disconnect the regulator from the bottle and remove the gas cylinder outdoors or
to a well ventilated area. Contact your gas supplier for assistance. DO NOT USE
THE HEATER.
(h) After leak testing is satisfactorily carried out close the back door of the heater.

It may be necessary to move the heater slightly to allow the regulator and hose
to fit in the back without kinking the hose

(i)

Need to regular checking and if necessary replacement the hose

HOW TO CHANGE A CYLINDER

1) Unplug the heater before take out the cylinder.
2) Turn off at the regulator and allow the heater to cool fully before removing

and replacing the cylinder. Do not attempt to replace the cylinder whilst the
heater is still running.

3) Cylinders must be replaced in a flame free environment.
4) Do not smoke while changing the cylinder.
5) When you need to replace your empty cylinder, turn the gas off at the valve or

regulator of the cylinder and take the empty cylinder out of the heater.

6)

Remove the regulator from the empty cylinder.

6

Summary of Contents for KF-001B

Page 1: ...NS IN A SAFE PLACE FOR FUTURE REFERENCE ONLY USE IN A WELL VENTILATED AREA USER MANUAL FOR MOBILE GAS HEATR KF 001B KF 001C WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE OR...

Page 2: ...from the cylinder Call your gas supplier immediately 14 After use turn off the appliance at the gas container valve 15 This appliance requires a hose and a regulator check with your gas supplier 16 O...

Page 3: ...0cm2 40cm2 2 70 cubic metres 7m 4m 2 5 70cm2 70cm2 3 105 cubic metres 105m 4m 2 5 105cm2 105cm2 Packing details When you receive a new heater you will find the below parts inside the carton 1 one piec...

Page 4: ...B Wall Mounted Installation Procedures Fig 02 Fig 03 Fig 04 Fig 05 Fig 01 01 02 03 3...

Page 5: ...d keep at least 50mm from the heater WARNING Heater must be mounted to maintain the minimum clearances shown in Fig 05 If possible provide greater clearances from the floor ceiling and joining walls F...

Page 6: ...CONSTRUCTION AND FUNCTION 1 Gas inlet connector 2 Wheel 3 Leg 4 Gas control knob 5 Piezo Ignition 6 Ignition handle 7 Burner 8 Safety Guard 9 Corner fixtor 10 Wall Mounted Bracket 10 Fig 06 Fig 07 5...

Page 7: ...of bubbles forming indicates a leak If a leak is found turn off at the regulator and disconnect the regulator from the bottle and remove the gas cylinder outdoors or to a well ventilated area Contact...

Page 8: ...er D Turn on the gas regulator 1 LIGHTING please see the picture Fig 09 Press the control button for 10 seconds at the Position 1 at the same time press the Piezo igniter key to lit with thumb finger...

Page 9: ...ing The heater can be turned off at the cylinder valve ONLY If the heater is not used for a period of time disconnect the regulator from the cylinder and replace any value protection plug or cover STO...

Page 10: ...nish MAINTENANCE 1 Check flexible tubing between regulator and heater regularly and replace if perished worn or damaged In any case replace tubing taking into consideration the expiration date 2 It is...

Page 11: ...essary Burner flame has extinguish during operation Run out of gas Change the gas bottle Thermal element has not been warm enough Try restarting Wing or draught has extinguished the flame Put the appl...

Page 12: ...duct name Gas Heater Standard EN 449 2002 A1 2007 Appliance category I3 I3B P 30 I3B P 50 I3P I3B P 37 Type of gas G30 G31 G30 G31 G30 Gas Pressure mbar 28 30 37 30 50 37 37 Injector s diameter mm 0 5...

Reviews: