3.1. Basic Specifications
ITEMS
SPECIFICATION
Measuring Type
Diffusion
Measuring Value Display
- LCD or OLED Display
- Green, Red, Yellow LED
- Sound Output(95dB)
Measuring Method
- Electro-Chemical Cell
- Heated-semiconductor Cell)
- Photoionization detector(PID)
Detectable Gas
Toxic Gas (Note 1)
Measuring Range
Capable to display 000.0 ~ 9999 (Note 1)
Accuracy
≤ ±3% / Full Range
Zero Drift
≤2% / Full Range
Response Time
Depends on Sensor Module.
Refer to Sensor Specification or Contact in case for Special Gas.
Approvals Classification
KCs: Ex d llC T6,T5,T4, IP65
ATEX/IECEX: II 2 GEx d IIC Gb T4~T6
SIL2, MED, ABS, DNV
Basic Interface
Analog 4-20mA current interface
HART Interface
HART REV7 (Option)
Option
HART Board
Warranty
Transmitter & Lamp
2Year
Sensor
1Year
※ Note1. Refer to the measured gas list for measured gases and their ranges. Contact us for special gas.
3.2. Mechanical Specifications
ITEMS
SPECIFICATION
Explosion-Proof Type
Explosion-Proof Enclosure
Dimension
- Transmitter: 136(W) × 166(H) × 110(D) mm
- Lamp: 83.8(W) × 85(H) × 48(D) mm
Weight including Sensor
App. 2.2kg
Mounting Type
Wall mount
Mounting Hole
Ø 7 ±0.1
Cable inlet
3/4" PF ( 1/2" or 3/4" NPT )
Body Material
Transmitter
Aluminum Alloy
Sensor
Stainless Steel (STS316)
Transmitter
PC
Sensor
Stainless Steel (SUS304)