10. Precautions before Installation
■ During wiring work, use explosion-proof cable gland at cable inlet or tightly seal cable conduit during metal cable wiring
construction to prevent spread of flames in case of explosion or movement of gas, etc. through the cable conduit within
50 mm. All materials including materials used for sealing of unused inlets must have safety certificates!
■ When connecting the equipment with cable, screw thread must be tightened 5 threads or more.
■ Work in conditions satisfying other [Standards for Selection, Installation, and Maintenance, etc. of Explosion-proof Electric
Machine and Equipment Wiring, etc. at Work Site]
[Figure 15. High-Pressure Packing Type]
[Figure 16. Y Sealing Compound]
Cable
Cable
Inside
Inside
Outside
Outside
Lead-in unit connector
Lead-in unit connector
Charging compound
Cable-fixing device
Pipe for piping
Cable-fixing device
Sealing ring
Sealing
ring
Connector
Pipe for piping
Compressed
element
Connector for fixing
compressed element