6.0

 

Maintenance & Service 

The ChipCHECK unit is designed to require a minimum amount of maintenance.  The sub-sections below 
provide the regular maintenance procedures required for the ChipCHECK unit. In the event of any 
equipment failure, Users are strictly forbidden to perform any kind of service.  Service activities are 
restricted to Gastops authorized technicians who have the appropriate laser safety training.   

6.1  Allowable User Maintenance  

The ChipCHECK system is contained within an enclosure that acts as protective shielding preventing all 
laser radiation above Class 1 to the Operator.  This section reviews the recommended, although 
infrequent, maintenance that will ensure the longevity and performance of the unit. 

It is important to note that this section covers only recommended maintenance and there is absolutely 
NO SERVICE ALLOWED by the User  where “service” is defined as any action requiring the removal or 
opening of an enclosure panel.  In the event that the unit requires service, then it shall only be serviced 
or repaired by Gastops authorized technicians.  

For the maintenance procedures discussed herein, there is no need to remove any covers or modify the 
unit.  The User is strictly forbidden from modifying the unit, removing any covers, or to alter, interfere, 
modify, remove, circumvent, defeat or de-active any safety system or interlocks (refer to Section 2.2.2). 

Both the Standardization and Calibration Patches are consumable and will require replacement every 
year.  When the Standardization patch is replaced, it is recommended that the  Containment Window 
(refer to Figure 6-1) either be cleaned or replaced.  This is due to the slow accumulation  of Laser 
Generated Air Contaminants (LGACs) that may occur after an extensive number of analyses.  Over time, 
if these containments become excessive, the overall performance of the unit may be affected.     

Figure 6-1 shows all of the components that are accessible during the maintenance of the unit.   

Finally, if the fuse blows, then the User is permitted to replace the fuse with the proper part.    To ensure 
the integrity of the unit, it is recommended that this fuse be sourced directly from Gastops. 

Note that, to ensure optimum performance and longevity of the equipment the Gastops in-service 
support package must be maintained throughout the life of the equipment. 

Summary of Contents for ChipCHECK CC120

Page 1: ...SIGNS DISCLOSED HEREIN ARE THE EXCLUSIVE PROPERTY OF GASTOPS LTD AND ARE NOT TO BE USED OR DISCLOSED TO ANY OTHERS WITHOUT THE WRITTEN CONSENT OF Gastops LTD ANY RECIPIENT BY ITS RETENTION AND USE AGR...

Page 2: ...unit requires service then it shall only be serviced or repaired by Gastops authorized technicians For the maintenance procedures discussed herein there is no need to remove any covers or modify the u...

Page 3: ...ng Once in Maintenance mode press the Conduct Maintenance button near the middle of the screen The Sample Receptacle will automatically displace further outside of the unit providing the required acce...

Page 4: ...n Figure 6 2 Maintenance Holder Receptacle Position Left Containment Window Assembly Right 6 1 2 Cleaning the Containment Window If the Containment Window is to be cleaned not replaced then the follow...

Page 5: ...wly drag the Isopropyl soaked cloth over the surface of the Containment Window pulling parallel to the exposed surface of the Containment Window ensuring no pressure is applied to the window itself Re...

Page 6: ...y Module Follow the set up instructions as described in Section 3 3 Figure 6 3 Power Entry Module and Main Power Switch 6 2 Unit Service No Allowable Service In the event of any equipment failure or c...

Page 7: ...designated customer support representative Refer to Section 8 0 Table 6 1 Basic Trouble Shooting Procedures Symptom Possible Remedy Software interface does not respond to user input Conduct a complet...

Page 8: ...on 5 4 The unit fails both Standardization and Calibration Power cycle the unit Perform the maintenance sequences defined in Section 6 0 Repeat Calibration and the complete Standardization If the unit...

Page 9: ...required Please call customer support Conduct a complete unit shutdown and power down Then power up and restart the unit as per Section 3 3 If this does not work then contact Gastops Customer Support...

Page 10: ...emovable foam insert protects the front face of the ChipCHECK unit When unboxing the unit this insert must be removed before the ChipCHECK can be removed from the transport case To remove the unit fro...

Page 11: ...d custom foam cut out Note that there is only one proper orientation for the unit to be placed otherwise the Transport Case will not close properly 6 Replace the instrument s accessory foam insert and...

Page 12: ...ions Foam insert removed Figure 7 4 Foam Insert Storage Locations Space for Operator s Manual located beneath ChipCHECK unit Storage slots beneath foam insert for Sample Cases Calibration Standardizat...

Page 13: ...200x Sample Patches 1x Standardization Standard 1x Calibration Standard 20X Sample Patch Cases 1x USB Ethernet Adapter Additional optional accessories may include the following External keyboard Exter...

Page 14: ...restrictions and conditions as set out in this publication 8 0 Customer Support Gastops technical support representatives for ChipCHECK can be reached at Phone 1 613 744 3530 Fax 1 613 744 8846 Toll...

Reviews: